Table of zones
A zone is represented by the number of LED flashes used by the system to
identify a particular type of input. Standard input assignments are listed
in the following table, along with spaces to write in any optional sensors
or switches that have been installed.
Zone
Description
Dealer installed options
1 Trunk
Pin
2
Instant trigger: a heavier impact
detected by the shock sensor
3 Door
switch
trigger
4
Instant trigger: For optional
sensors
5 Ignition
trigger
6 Hood
Pin
➤
Interpreting zone diagnostics
Warn Away responses are not reported by arming or disarming
diagnostics. If you receive a Bypass notification when arming or a
Tamper Alert notification when disarming, look at the LED.
Active or triggered zones will be indicated by a pattern of blinks by the
LED.
For example: If zone 3 was active or triggered, the LED will blink three
times with a two-second pause. Then it will blink three times again, and
repeat until the ignition is turned on.
38