© 2003 Directed Electronics, Inc. Vista, CA
49
shutdown diagnostics
1. With the ignition OFF, press and
HOLD
the Valet/Program button.
2. Turn the ignition ON and then back OFF while
HOLDING
the Valet/Program button.
3. Release the Valet/Program button.
4. Press and release the Valet/Program button. The LED will report the last shutdown for one minute or until
the ignition is turned on.
long term event history
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full
trigger, the older of the two triggers in memory will be replaced by the new trigger. To access long term event
history:
1.
With the ignition off, press and
HOLD
the Valet®/Program switch.
2.
Turn on the ignition.
LED FLASHES
SHUTDOWN MODE
One
Timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Transmitter shutdown (or optional push-button)
Six
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
Seven
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Eight
Wait-to-start timed out
to perform shutdown diagnostics