TECHNICAL SPECIFICATIONS 

 

Model 

 

JPX1000RM 

JPX2000RM 

Capacity    (VA) 

1000VA 

1920VA 

Capacity    (Watts) 

600W 

1200W 

Input 

Input Voltage Range 

82V~148V 

Frequency 

50/60Hz auto sensing 

Output 

On Battery Output Voltage 

Pure Sine Wave at /-10% 

On Battery Output 

Frequency   

50/60 Hz +/-1% 

Overload Protection 

Yes 

AVR Function 

Boost Function 

Yes                                                                                                                                                                                                                                                                                 

Buck Function 

Yes 

Physical

 

Total # of UPS Receptacles 

Nema 5-15R *8 

Maximum Dimensions   

(H x D x W) 

88mm x 400mm x 433mm 

Battery

 

Sealed Maintenance Free 

Lead Acid Battery 

24Vdc 

Typical Recharge Time 

8 Hours 

Warning Diagnostics 

Indicators 

LCD 

Communication

 

Communication port

 

USB,RS232 

Environmental

 

Operating Temperature 

32

F to 122

F ( 0

C to 40

C ) 

Operating Relative Humidity 

0 to 90% NON-CONDENSING 

Management

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 

 

TROUBLE SHOOTING

 

 

Problem 

Possible Causes 

Remedy 

Abnormal 

Mains normal but not 

works in AC mode 

1.  AC Input    missing 

1. Check AC input connection. 

2. Input Breaker is tripped 

2. Unplug the power cord of the UPS 

then press the circuit breaker knob. 

The UPS will not turn on. 

 

The on/off Button is 

designed to prevent damage 

by rapidly turning it off and 

on. 

Turn the UPS off.    Wait 10 seconds 

and then turn the UPS on. 

The unit is not connected to 

an AC outlet. 

The unit must be connected to a 

100-127V 50/60Hz outlet.     

The battery is worn out. 

Contact technical support. 

Mechanical problem. 

Outlets do not provide 

power to equipment 

Circuit breaker is tripped due 

to overload 

Turn the UPS off and unplug at least 

one piece connected equipment. 

Unplug the power cord of the UPS then 

press the circuit breaker knob. 

Batteries are discharged 

Allow the unit to recharge for at least 4 

hours. 

Unit has been damaged by a 

surge or spike. 

Contact technical support.   

Alarm code A01 

Site Fail: 

Line and neutral conductors 

of UPS Input are reversed or 

the Ground is disconnected. 

Check the input plug and socket. 

Alarm code A06 

Battery low: 

Battery capacity is low, UPS 

will turn off soon 

1. Shut off non-essential equipment. 

2. Save your data and turn off the 

computer. 

Alarm code A14 

Overload: 

Your equipment requires 

more power than the UPS 

can provide. 

1. Shut off non-essential equipment. 

Alarm code A18 

Over Temperature 

1. Shut off non-essential equipment. 

2. Check the fan for operation and if 

the ventilation hole has been covered. 

 

Fault

 

Fault code F09 

Output Short : 

Output circuit short. 

1. Shut down the UPS   

2. Your attached equipment may have 

problems, please remove them and 

check again. 

Fault code F14 

Overload: 

Your equipment requires 

more power than the UPS 

can provide.   

It will shutdown.   

Shut off non-essential equipment. If 

this solves the overload problem, the 

UPS will transfer to normal operation. 

Fault code F18 

Fan fail : 

Fan has been damaged.   

1.Shut down the UPS   

2.Replace the fan 

Fault code F19 

Over Temperature 

1. Shut down the UPS. Restart the 

UPS to Check the fan for operation 

and if the ventilation hole has been 

covered 

2. Contact technical support for repair. 

 

SOFTWARE DOWNLOAD

 

 

Power Master management software provides a user-friendly interface for your power systems. The 
graphic user-interface is intuitive and displays essential power information at a glance. Please follow 
procedure below to install the software. 

 
 
Installation procedure: 

1. 

Download Power Master from the 
website: 

http://www.powermonitor.software/

 

2. 

Double-click the file and follow the 
installation steps. 

When your computer restarts, the Power 
Master software will appear as a blue 
icon located in the system tray. 

 

 

All rights reserved. Reproduction without permission is prohibited. 

 

 

 

                               

 

 

Reviews: