Installing in the Unit Continued
Homeruns should not exceed maximum cable
distance
RG6 should not exceed 150’
RG11 should not exceed 200’
Line amplifiers are
NOT
approved and will not be used
New homerun cabling should be installed
In the most direct route available between the enclosure
and the unit
Professionally
Properly attached to the building (where/when applicable)
Loose cabling should be tied together
Multiple homerun cables may be installed along the same cable path
Cables should be neatly bundled together
Zip ties should NOT be evenly spaced along the cable route
Maintain proper bend radius of the cable type installed