Danish Interpretation Systems
User Manual
5.4.8
Connecting an emergency signal
To use the emergency signal function, a switch
(normally‐open) must be connected to the emergency
switch connector. When the switch is closed an
“Emergency Evacuation Message (EEM)” audio signal
present on the ‘In 2’ input is distributed to all output
channels, overriding all other audio inputs.
Important:
The level of the signal must be controlled
externally.
5.5
Using the Interactive Menu
5.5.1
Overview
The major configurations and operation options of
the CU 5905 can be set via an interactive menu, using
the 2x20 character OLED display and the 5‐button
keypad.
‘Figure 5.3 A’ gives an overview of the menu
structure, however for a general description of the
settings in the menu refer to the section ‘5.6 Web
Browser’, where all CU 5905 settings are explained.
Figure 5.5-A
Menu overview
5.5.2
Navigate through the menu
Navigation in the menu and changing parameters is
done by activation the 5‐button keypad:
Cycle through the menu items (Blue marking)
with the four ‘arrow’ buttons (Left‐Right, Up‐
Down).
Navigate to a settable option (Green marking).
Cycle through the available values for a settable
option using the ‘arrow’ buttons Up‐Down.
Press the ‘Enter’ button in the centre to accept the
value. Pressing the Enter button concludes the
selection made, and at the same time it indicates a
confirmation of the possible changes made within the
selection. Please note that some changes are applied
mmediately, and confirmation is thus not required.
i
User Manual DDS 5900
23