Danish Interpretation Systems
User Manual
Manual 01 18 04450
11
CM/DM 6060F/6510F Chairman/Delegate Units
The following tables show the maximum number of
units, which can be connected to the two outputs
(A1 or A2) on a CU 6005 Central Unit in total or to
each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX
6010 Extension Unit or to the output of a PS 6000
Power Supply.
Length of Feeding Cable
Type CAT5 AWG24
Length of inter connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of
CM/DM 60x0 pr output
10 m
1 m
39 m
30
30 m
1 m
56 m
27
50 m
1 m
73 m
24
100 m
1 m
115 m
16
150 m
1 m
160 m
11
10 m
2 m
64 m
28
30 m
2 m
78 m
25
50 m
2 m
94 m
23
100 m
2 m
130 m
16
150 m
2 m
170 m
11
CM/DM 6560F Chairman/Delegate Units
Length of Feeding Cable
Type CAT5 AWG24
Length of inter-connecting
Cable, Type CAT5 AWG24
Total cable length
Max. number of CM/DM
60x0 pr output
10 m
1 m
35 m
27
30 m
1 m
53 m
24
50 m
1 m
70 m
21
100 m
1 m
113 m
14
150 m
1 m
159 m
10
10 m
2 m
58 m
25
30 m
2 m
72 m
22
50 m
2 m
88 m
20
100 m
2 m
126 m
14
150 m
2 m
166 m
9