background image

Danish Interpretation Systems 

 

User Manual 

 

Manual 01 18 04450 

 

14

Appendix 

Technical appendix 

Cabling 

CAT5  

The  DCS  6000  system  uses  CAT5,  CAT5e  or 
CAT6  FTP  or  STP  cables  with  screened  RJ45 
connectors.  

EIA 568-B wiring shall be used. 

It  is  important  to  use  only  FTP  or  STP 
(screened)  cables  and  screened  RJ45  connectors 
and not UTP cable, which is unscreened. 

How to wire a CAT5 (EIA 568-B) Cable: 

Pin  Function 

Connector #1  Connector #2 

In-going + 

ORG/WHT 

ORG/WHT 

In-going - 

ORG 

ORG 

+48V 

GRN/WHT 

GRN/WHT 

0V 

BLU 

BLU 

0V 

BLU/WHT 

BLU/WHT 

+48V 

GRN 

GRN 

Outgoing - 

BRN/WHT 

BRN/WHT 

Ou  BRN 

BRN 

 

Note.   If other colour codes are used then the four 

pairs are connected as follows: 

Pair 1: 

Pin 1 & 2 

Pair 2:  

Pin 3 & 6 

Pair 3: 

Pin 4 & 5 

Pair 4: 

Pin 7 & 8 

The phase of the pairs must be correct and the 
wiring spec. as stated in CAT5 (EIA 568-B) have to 
be followed. 

Note:  CAT6  cables  can  normally  only  be 
terminated  in  sockets  (female)  and  not  in  cable 
plugs.  

CAT6 can thus only be used for longer cable draws 
terminating in wall outlets or patch panels. 

Accessories (not supplied) 

Cat 5e Connection Cables (AWG24) 

EC 6000-..5 Connection Cable 0.5 m......................10 03 12500 

EC 6000-01 Connection Cable 1 m.........................10 03 13101 

EC 6000-02 Connection Cable 2 m.........................10 03 13201 

EC 6000-05 Connection Cable 5 m.........................10 03 13501 

EC 6000-10 Connection Cable 10 m.......................10 03 14102 

EC 6000-20 Connection Cable 20 m.......................10 03 14202 

EC 6000-50 Connection Cable 50 m.......................10 03 14502

Technical specifications

General 

Power consumption  .................................................max. 150W 

Mains voltage:  ........................................100 - 240V, 50...60Hz 

Supply voltage for units............................................ 48V/125W 

Temperature to guarantee specified performance 

..............................5 Deg C. to 40 Deg C. (35 to 80% humidity) 

Storage temperature 

.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity) 

Weight..................................................................................1 kg 

Dimensions (W x H x D).................... 100 (125) x 50 x 205 mm 

Dimensions in bracket are including the fixing bracket  

Accessories supplied .................................................Main cable 

Connectors 

DCS-LAN loop through ....................................... 2 pieces RJ45 

Specifications are subject to change without notice. 

 

Summary of Contents for PS 6000

Page 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System PS 6000 Power Supply ...

Page 2: ...rpretation Systems User Manual Copyright 2007 DIS PS6000 REV B DOC 21 05 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher ...

Page 3: ... 6 Conference equipment and channel selectors 6 Operating instructions 7 PS 6000 Power Supply 7 General description 7 Features 7 Connectors 7 System design 7 Use of PS 6000 8 System Setup 9 General guidelines 9 Max number of units to be connected 10 CM DM 60x0P Chairman Delegate Units 10 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box 10 CM DM 6060F 6510F Chairman Delegate Units 11 CM DM ...

Page 4: ... personnel Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Set the Power switch to OFF if it is not used for several days The equipment must be connected to earth Installation precautions Allow adequate air circulation to prevent internal heat built up Do not place the unit on a surface rugs blankets etc...

Page 5: ...he system Using screened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable through serial PC connection RS232 or RS422 Can be operated with or without a PC Added functionality and comprehensive features provided by SW 6000 software package running on PC RS232 RS...

Page 6: ... portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two built in channel selectors and XLR microphone connector CM DM 6060F Conference Unit flush mounted with one built in channel selectors CM DM 6510F Conference Unit flush mounted with Chip card and 3 votin...

Page 7: ...res the following connectors Power connector Connection for main power Loop through connectors RJ45 connector 2 pieces DCS LAN connectors used for connection to the CU 6005 6010 and for connection to other units with DCS LAN connectors such as more PS 6000 Power LED Those green LED light up when Power is available on the connector next to the LED System design There are no settings to be done on t...

Page 8: ... 6000 chain where extra power is needed The PS 6000 is used when extra power is needed typically where long feeding cables are needed A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable The following schematic shows various ways in how to use the PS 6000 Power Supply ...

Page 9: ...m the PS 6000 to the units connected If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long and or the cables are long between the units Please consult the next section Max Number of units to be connected If the last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termi...

Page 10: ...umber of CM DM 60x0 pr output 10 m 1 m 51 m 42 30 m 1 m 67 m 38 50 m 1 m 83 m 34 100 m 1 m 123 m 24 150 m 1 m 165 m 16 10 m 2 m 88 m 40 30 m 2 m 98 m 35 50 m 2 m 108 m 30 100 m 2 m 142 m 22 150 m 2 m 180 m 16 CM DM 60x0P Chairman Delegate Units JB 6002 Junction Box This configuration shows two CM DM 60x0 Delegate Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB 6...

Page 11: ... AWG24 Length of inter connecting Cable Type CAT5 AWG24 Total cable length Max number of CM DM 60x0 pr output 10 m 1 m 39 m 30 30 m 1 m 56 m 27 50 m 1 m 73 m 24 100 m 1 m 115 m 16 150 m 1 m 160 m 11 10 m 2 m 64 m 28 30 m 2 m 78 m 25 50 m 2 m 94 m 23 100 m 2 m 130 m 16 150 m 2 m 170 m 11 CM DM 6560F Chairman Delegate Units Length of Feeding Cable Type CAT5 AWG24 Length of inter connecting Cable Typ...

Page 12: ...are the number of units which could have been connected CU EX but where the total number of units has been lowered due to the restriction of the maximum length of cable 200 m IS 6132P Interpreter Units This table shows the maximum number of IS 6132P Interpreter Sets which can be connected The numbers are with no audio in loudspeaker no loudspeaker connected to each unit If loudspeakers are used th...

Page 13: ... 0 150 m 5 m 5 4 4 CS 6032F Channel Selector w back light on Length of Feeding Cable Type CAT5 AWG24 Length of Inter connecting cable Type CAT5 AWG24 Total cable length Max number of CS 6032 pr output 30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 67 10 m 2 m 200 m 96 30 m 2 m 200 m 86 90 50 m 2 m 200 m 76 85 100 m 2 m 200 m 51 70 150 m 2 m 200 m 26 60 Numbers in are th...

Page 14: ...les can normally only be terminated in sockets female and not in cable plugs CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels Accessories not supplied Cat 5e Connection Cables AWG24 EC 6000 5 Connection Cable 0 5 m 10 03 12500 EC 6000 01 Connection Cable 1 m 10 03 13101 EC 6000 02 Connection Cable 2 m 10 03 13201 EC 6000 05 Connection Cable 5 m 10 03 13...

Reviews: