Installation Diagrams - Introduction to Installation Diagrams
3 - 1
Introduction to Installation Diagrams
•
The installation options listed on the following pages may or may not be reimbursable installations. Refer to the latest
Business Rules to confirm reimbursement status.
•
Installations must use all Legacy LNBFs and switches, or all DISH Pro/DISH Pro Plus LNBFs and switches. Do not mix
and match Legacy components with DISH Pro/DISH Pro Plus components.
•
If upgrading from Legacy LNBFs and switches to DISH Pro/DISH Pro Plus LNBFs and switches, ensure all Legacy
components (for example, power inserters) are removed. Remove DP Adapters from any Legacy receivers connected
to DISH Pro Plus components.
•
Maximum distance between the furthest LNBF and farthest receiver is 200 feet for DP/DP Plus receivers; 100 feet for
Legacy receivers (four-digit model numbers). Maximum cable length from a wing dish with a compatible DISH Pro
LNBF to a DISH Pro Plus LNBF’s
LNB I
N
port is 80 feet with 120 feet from DPP LNBF to receiver for a total of 200 feet.
•
Ensure all components (for example, cable, ground blocks, diplexers, splitters, line amps, barrel connectors, wall plates
and surge protectors) are rated for DISH Pro/DISH Pro Plus installations (rated to 2150 MHz and pass DiSEqC 22 KHz
tone—review the
DISH Network Approved Accessories List
), also referred to as
DP compatible
.
•
Refer to the
LNBFs and Switches
and
Dish Antennas
sections for Legacy receiver installation considerations.
Abbreviations
•
DP: DISH Pro
•
DPP or DP Plus: DISH Pro Plus