User manual in Original
Doc. ref: 500A_MB_am_en_210602
DISPERATOR AB
Tel: 08-724 0160
E-mail: info@disperator.se
Mälarvägen 9, 141 71 Segeltorp
Web page: www.disperator.se
41 / 41
40 / 41
9.6. Overhaul and Maintenance Intervals
Description:
Interval:
Refers to:
Cleaning of the machine
After daily use
See section 8.2 in this user manual
Check of the line strainer in the flush
water pipe
First time after a month use,
then when needed
See section 8.3.2, item 3 in this user manual
Preventive maintenance - small
First time after a month use,
then year 1, year 4, year 7
…........ etc.
For this maintenance (overhaul) please note
that no parts need to be exchanged. See
section 9.3 in this user manual in terms of:
*Overhaul of protection safety,
*Overhaul of assembly and connections,
*Overhaul of all mechanical and electrical
connections,
*When needed, training of personal.
Preventive maintenance - medium
Year 2, year 5, year 8 …........
etc.
* Preventive maintenance – small according
to above.
* Replacement of rubber seals with Position
No. P14 and P17 (Spare Part No. -05 and -08)
in section 9.2 of this user manual.
Preventive maintenance - large
Year 3, year 6, year 9 …........
etc.
* Preventive maintenance - medium
according to above.
* Replacement of parts included in Service
Package 1 according to section 9.2 of this
user manual. If needed due to long and hard
operating times of disposer, please also
inspect if the carrier (Pos. No. P2, Spare Part
No. -18) as described in section 9.4, item 16
need to be ordered and exchanged. For those
disposer models that have a large inlet with
noise damping seal (shown as Pos. No. 17 in
the table in the end of section 9.2), please
also consider if this seal due to wear has
lost its elasticity and therefore needs to be
replaced.
Replacement of parts due to wear
After approx. 9000 operating
hours
Service package 2 according to section 9.2 in
this user manual
Exchange of other parts
When needed
Summary of Contents for EXCELLENT 500A-MB Series
Page 2: ......