31. Insert the dust hose (9/10) into the front panel.
32. Screw outlet connection (9/8) onto the end shield (9/9). Use thread tape to lock and seal the
outlet connection to the end shield so that it stays firm. The measurement between the outlet
connection (10/8) and the end shield (10/9) should be 2 to 8mm. Make sure that the threaded
holes, 4 pcs. in the outlet connection are positioned as shown in picture 10 (tolerance ± 5˚).
33. Assemble the outlet (9/5) on the outlet connection, 4 screws (9/6) with the O-ring (9/7) that
seals between these two parts.
34. Assemble the dust hose (9/10) with hose clamp on the outlet (9/5).
35. Connect the dust hose with inlet pipe (9/11) to the cover with dust collecting bag (9/4) and refit
it to the cabinet.
36. Make sure that the O-ring (3/12) on the inlet feeding tube (9/3) and its front panel sealing
surface are clean before installing the tube on the front panel. With care that the key (3/29)
slides into the interlock switch (3/28), lift the inlet feeding tube onto the front panel and fix it
with the knob.
37. Mount the top cover (9/1) with two screws (9/2).
38. Reconnect electricity according to the above section 6.2.
39. Test the glass crusher according to the above section 6.3 of this user manual.
Picture 9
Picture 10
Summary of Contents for EXCELLENT 550A-GKF Series