User Manual in Original
Dok. ref: 550A_GKF_am_sv_210525
DISPERATOR AB
Tel: 08-724 0160
E-mail: info@disperator.se
Mälarvägen 9, 141 71 Segeltorp
Web page: www.disperator.se
30 / 35
9.6. Intervals for Overhaul and Maintenance
Description of activity:
Interval:
Comments:
Cleaning of the machine.
Daily
See section 8.2. in this user manual.
Checking the glass crusher’s automatic
vacuum function for collection of glass
dust.
Daily
Start the glass crusher and place a thin
flat paper over the entire opening of
the inlet feeding tube. The paper should
then remain on the tube by the created
under pressure in the crusher. If the
paper drops, the dust collecting bag is
clogged and must be replaced. If the
paper drops even though the bag is
not clogged, perform the checks as per
section 9.3.2.
Overhaul of:
•
interlock switch,
•
vacuum function for dust,
•
assembly.
First time after a
month, then when
needed.
See section 9.3. in this user manual.
Preventive maintenance.
After crushing of
about 20.000 glass
bottles or 5 years
(whichever occurs
first).
Replacement of parts included in
Service Package 1 according to section
9.7.1. in this user manual.
Exchange of parts subject to wear.
After crushing of
about 40.000 glass
bottles.
Replacement of parts included in
Service Package 2 according to section
9.7.1. in this user manual.
Other parts.
When needed.
Summary of Contents for EXCELLENT 550A-GKF Series
Page 2: ......