Prepare - 24
SK500 Operator’s Manual
Classify Jobsite
CMW
Classify Jobsite
Inspect Jobsite
•
Inspect jobsite and perimeter for evidence of underground hazards, such as:
– “buried utility” notices
– utility facilities without overhead lines
– gas or water meters
– junction boxes
– drop boxes
– light poles
– manhole covers
– sunken ground
•
Follow U.S. Department of Labor regulations on excavating and trenching (Part 1926, Subpart P) and
other similar regulations.
•
Contact One-Call (888-258-0808) and any utility companies which do not subscribe to One-Call.
•
Have an experienced locating equipment operator sweep area within 20 feet (6 m) to each side of
work path. Verify previously marked line and cable locations.
•
Mark location of all buried utilities and obstructions.
•
Classify jobsite.
Select a Classification
Jobsites are classified according to underground hazards present.
If working . . .
then classify jobsite as . . .
within 10 ft (3 m) of a buried electric line
electric
within 10 ft (3 m) of a natural gas line
natural gas
in sand or granite which is capable of producing crystalline silica
(quartz) dust
crystalline silica (quartz) dust
within 10 ft (3 m) of any other hazard
other
NOTICE:
If you have any doubt about jobsite classification, or if jobsite might contain unmarked
hazards, take steps outlined previously to identify hazards and classify jobsite before working.
Summary of Contents for SK500
Page 1: ...SK500 Operator s Manual 054 091 Issue 2 0 CMW...
Page 9: ...Contents 8 SK500 Operator s Manual CMW...
Page 33: ...Drive 32 SK500 Operator s Manual Shut Down CMW...
Page 65: ...Service 64 SK500 Operator s Manual 500 Hour CMW...
Page 72: ......
Page 73: ......
Page 74: ...SK500 Operator s Manual Service Record 73 CMW Service Record Service Performed Date Hours...
Page 75: ...Service Record 74 SK500 Operator s Manual CMW Service Performed Date Hours...