Service - 51
10 Hour
CMW
Kohler
Check air filter every 10 hours. Replace as needed.
1.
Open air filter housing at latches (1).
2.
Remove and inspect primary (2) and secondary (3) elements.
3.
Wipe inside of housing and wash end cup.
4.
Insert primary and secondary elements.
5.
Close air filter case.
Check Track Tension
Check track tension every 10 hours and adjust as needed. Turn bolt (1) clockwise to tighten and
counterclockwise to loosen. Track tension is correct when dimension A is 10” (254 mm).
t05om008c.eps