4. TESTING THE AUTOMATIC SYSTEM WITH EL16 ELECTRONIC BOARD
4.1 Checking the dip-switches
4.2 Functional test
Wire up as shown in fig. 3, close the contacts 41-6, 41-8, 1-9.
Connect the transformer to mains (230 V~/50 Hz).
Give the following commands to the electric board and visually check for correct response and straight and smooth running.
ACTION
OUTCOME
Electric board turned on
- green LED lit
Command 1-3A and OPEN button (impulsive)
- closure manoeuvre
Command 1-4 (impulsive)
- opening manoeuvre
Command 27-3B (impulsive) and RP trimmer at minimum
- partial opening manoeuvre
Close contacts 1-2
- re-opening
Command 41-6 during opening (opening contact)
- reduce in the last 500 mm of the door stroke when the con-
tact is opened.
Command 41-8 during closure (contact open)
- the gate should open when the optical alignment between TX
and RX is broken.
Control of the photocell card during the closure phase:
- connect the CelPR
- stop for the duration of the command
Command 1-9 (contact open)
- reset, encoder zero setting
Command 1-29 and RESET button (impulsive)
- reset, encoder data reset
4.3 Chaos test
Send repeated open and close commands so as to cause the wing or wings to continuously reverse direction of movement without
stopping (for at least 1 minute). Check that the automation system does not fail to appropriately keep wing position under control
nor cause the wing or wings to slam, and that no logic malfunction occurs.
4.4 Checking the trimmers
4.5 Default setting
Set the following configurations at the end of the test:
-
all trimmers at minimum;
-
DIP1 is dependent on the type of automation; DIP2=ON;
-
all DIR dip-switches in the OFF position;
-
disconnect batteries (if installed), checking that the electric board is not being powered by them (press RESET command).
4.6 General controls
-
Control the length of the casing, the passage width and the width of the leaf.
-
Tie the power supply cable and command cables with related channels.
-
Apply the casing seal.
-
Perform a general check (belt tension, screw tightness, etc).
-
Fill-in and apply the CE label.
ACTION
OUTCOME
DIP1 = OFF for REX2 and REX1-DX
DIP1 = ON for REX1-SX
- changing the opening direction
DIP2 = ON for REX
- automation type selection
Warning: DIP2 must be set to ON
DIP1 = ON
- battery function, if present, in the event of blackout
DIP2 = OFF
- in the event of blackout, the automation with the batteries pre-
sent performs the last opening manoeuvre and then switches
off
DIP3 = OFF for REX
- block type selection
Warning: DIP3 must be set to OFF
DIR
ACTION
OUTCOME
TC trimmer adjustment
- variation of the automatic closure time
R1 trimmer adjustment
- variation of the force on obstacles
RF trimmer adjustment
- variation of the motor power
VA trimmer adjustment
- variation of the opening speed
VC trimmer adjustment
- variation of the closing speed
RP trimmer adjustment
- variation of the partial opening