background image

7

x

INSTALLATION

The sensor should be 

fixed firmly to avoid 

extreme vibrations.

Do not cover the sensor.

Avoid moving objects 

and light sources in 

the detection field.

Avoid highly 

reflective objects in 

the infrared field.

It is recommended to clean 

the optical parts at least once 

a year or more if required due 

to environmental conditions.

Do not use aggressive 

products to clean 

the optical parts.

• 

The device cannot be used for purposes other than its intended use. All other uses cannot be 

guaranteed by the manufacturer of the sensor.  

• 

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the 

sensor and the door system in compliance with applicable national and international regulations and 

standards on door safety. 

• 

The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate 

adjustments of the sensor.

Only trained and 

qualified personnel 

may install and setup 

the sensor. 

The warranty is invalid if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Always test the good 

functioning of the 

installation before 

leaving the premises.

The door control unit 

and the door cover 

profile must be correctly 

earthed. 

MAINTENANCE

SAFETY

LED-SIGNAL

Motion 
detection

Presence 
detection

LED flashes

LED flashes 
quickly

LED is off

LED flashes 
x times

LED flashes 
red-green

Summary of Contents for PAS024AMR

Page 1: ...D A N C E W I T H 1 LCD 2 radar antenna narrow field 3 radar antenna wide field 4 IR curtain width adjustment 5 IR lenses DESCRIPTION 6 cover 7 main connector 8 main adjustment knob 9 IR curtain angle adjustment knob User s Guide for product version 0403 and higher See product label for serial number ENGLISH OPENING SAFETY SENSOR FOR AUTOMATIC SLIDING DOORS IN EMERGENCY EXITS according to EN 16005...

Page 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Page 3: ...YELLOW WHITE PINK RED BLUE YE BK WH BK Output status when sensor is operational For compliance with EN 16005 and DIN 18650 connection to door controller test output is required Current source output for emergency exits POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR EMERGENCY EXITS SENSOR IMPORTANT The radar output parameter has to be set to current output factory value Door ...

Page 4: ... outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weath...

Page 5: ...size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence motion and presence opening output is active in case of 0 motion detection 1 motion or presence detection 2 motion and presence detection 20 min 60 min infinite service mode no IR detection during 15 minutes maintenance This value excludes conformity of the door system to EN 16005 and DIN 18650 high m...

Page 6: ... presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Replace sensor ORANGE LED flashes 6 x ORANGE LED flashes 7 x Faulty radar sensor output Replace sensor The internal test of ...

Page 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Page 8: ...ing is active by default EN ISO 13849 1 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle EN 16005 protective devices DIN 18650 1 protective devices EN 12978 Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW cm2 Open collector tra...