ENGLISH

GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally competent personnel only. The installation, the electrical connections

and the settings must be completed  in conformity with good workmanship and with the laws in force.
Read the instructions carefully before beginning to install the product. Incorrect installation may be a source of danger.
Packaging  materials (plastics, polystyrene, etc) must not be allowed to litter the environment and must be kept out  of the reach of children
for whom they may be a source of danger.
Before beginning the installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of flammable gas or fumes represents a serious threat to
safety.
Before installing  the motorisation device, make all the structural modifications necessary in order to create safety clerance and to guard
or isolate all the compression, shearing,  trapping and general danger areas.
Check that the existing structure has the necessary strength and stability.
The manufacturer of the motorisation device is not responsible for the non-observance of workmanship in the costruction of the frames to
be motorised , nor for deformations that may be occur during use.
The safety devices (photoelectric cells, mechanical obstruction sensor, emergency stop, etc) must be installed taking into account: the
provisions and the directives in force, good workmanship criteria, the installation area, the funtional logic of the system and the forces
developed by the motorised door or gate.
The safety devices must protect against compression, shearing, trapping and general danger areas of the motorized door or gate.
Display the signs required by law to identify danger areas.
Each installation must bear a visible indication of the data identifying the motorised door or gate.
Before connecting to the mains check that the rating is correct for the destination power requirements.
A multipolar isolation switch with minimum contact gaps of 3 mm must be included in the mains supply.
Check that upstream of the electrical installation there is an adequate differential switch and a suitable circuit breaker.
Ensure that the motorised door or gate has an earth terminal in accordance with the safety regulations in force.
The manufacturer of the motorising device declines all responsability  in cases where components which are incompatible with the safe
and correct  operation of the product only original spare parts must be used.
For repairs or replacements of products only original spare parts must be used.
The fitter must supply all information corcerning the automatic, the manual and emergency operation of the motorised  door or gate, and
must provide the user the device with the operating instructions.
It is recommended that antistatic conductive earthed arm bands be worn when manipulating electronic parts.

MACHINERY DIRECTIVE
Pursuant to Machinery Directive (98/37/CE) the installer who motorises a door or gate has the same obligations as the manufacturer of
machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The technical file must
  be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the
  motorised door);
- draft the EC declaration of conformity in accordance with Annex II-A of the Machinery Directive;
- affix the CE marking on the power operated door in accordance with point 1.7.3 of Annex I of the Machinery Directive.
For more information consult the “Technical Manual Guidelines” available on Internet at the following address: www.ditec.it

DECLARATION BY THE MANUFACTURER

(Directive 98/37/EEC, Annex II, sub B)
Manufacturer:

DITEC S.p.A.

Address:

via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY

Herewith declares that the electromechanical barrier UP4EHS
- is  intended  to be incorpored into machinery or to be assembled with other machinery to constitute machinery convered by Directive

98/37/EEC, as amended;

- is in conformity with the provisions of the following other EEC directives:

Electromagnetic Compatibility Directive 89/336/EEC, as amended;
Low Voltage Directive 73/23/EEC, as amended;

and furthermore declares that it is not allowed to put the machinery into service until the machinery into which it is to be incorporated or
of which it is to be a component has been found and declared to be in conformity with the provisions of Directive 98/37/EEC and with
national implementing legislation.
Caronno Pertusella, 22/05/2001.

 Fermo Bressanini
    (Chairman)

APPLICATIONS

·

Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible
weight). A reduction in performance is to be expected when the access is made to operate at the maximum permissible weight.

·

Service class, running times, and the number of consecutive cycles are to be taken as merely indicative having been statistically
determined under average operating conditions, and are therefore not necessarily applicable to specific conditions of use. During
given time spans product performance characteristics will be such as not to require any special maintenance.

·

The actual performance characteristics of each automatic access may be affected by independent variables such as friction, balanc-
ing and environmental factors, all of which may substantially alter the performance characteristics of the automatic access or curtail
its working life or parts thereof (including the automatic devices themselves). When setting up, specific local conditions must be duly
borne in mind and the installation adapted accordingly for ensuring maximum durability and trouble-free operation.

UP4EHS

Service life

Applications

2

(minimum 5÷10 years of working life with 20÷10 cycles a day)

LIGHT  (For vehicle or pedestrian accesses to single-
family or semi-detached homes with infrequent use).

Summary of Contents for UP4EHS

Page 1: ...llation et d entretien pour barri re lectrom canique Montage und Wartungs handbuch f r E l e k t r o m e c h a n i s c h e Torschranke Manual de instalaci n y manutenci n para barrera electromec nica...

Page 2: ...P4EHS 4x0 5 mm 4 UP AF SOLARP SOLARKS 2x1 5 mm RX 4x0 5 mm RX 4x0 5 mm 1 6 3 6 2 5 2x1 5 mm TX 4x0 5 mm 6 TX 4x0 5 mm Impianto tipo Standard installation Installation type Standard Montage Instalaci n...

Page 3: ...3 DITEC S P A IP1597 UP4EHS 270 245 182 1000 905 150 180 220 110 9 7 10 8 11 15 16 14 18 17 15 13 12 20 19 Fig 2 Fig 3 Fig 4 50 12 5...

Page 4: ...4 DITEC S P A IP1597 UP4EHS 21 16 22 23 21 16 22 23 14 DX SX UP4EHS DIP2 OFF UP4EHS DIP2 ON Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 DX SX...

Page 5: ...power supply M P P BAT ENCODER Q E SolarUH RESTART OPEN SAFETY VM R1 TC F2 F3 M M 14 0 1 2 3 4 5 8 9 30 1 2 ON 12V 14W 12V 14W Nero Black Rosso Red 12 V 2 Ah 12 V 2 Ah KIT SOLARP KEY RELEASE 0 1 2 3 4...

Page 6: ...e le informazioni relative al funzionamento automatico manuale e di emergenza della porta o cancello motorizzati e consegnare all utilizzatore dell impianto le istruzioni d uso La manipolazione delle...

Page 7: ...e 30x100 luce netta 4500 mm UPGR Siepe in alluminio L 2000 mm UP4M Molla 5 UPC Confezione nr 10 catarinfrangenti rossi UP4MP Molla 3 5 UPAF Appoggio fisso UPSN Snodo per bracci UP4BC 4BL RHIPBG50 HIPB...

Page 8: ...centro o tendente verso l alto fig 6 Il sistema di leve che sostiene le molle per motivi di sicurezza costruito in modo da avere una posizione stabile con braccio completamente aperto o completamente...

Page 9: ...ntrambe le automazioni ponticellare 1 2 sia su A che su B impostare su A e su B lo stesso tempo di TC RESTART Inserimento manuale batteria Q E in stand by Il Q E normalmente in stand by il consumo di...

Page 10: ...e schiacciare il tasto RESTART e se il problema rimane verificare e ricaricare le batterie mediante carica batterie non di nostra fornitura In presenza di una sufficiente luce solare i pannelli inizia...

Page 11: ...o Non opporsi al moto della porta o cancello motorizzati poich pu causare situazioni di pericolo Non trattenere o appendersi all asta della barriera quando in movimento Non permettere ai bambini di gi...

Page 12: ...arm bands be worn when manipulating electronic parts MACHINERY DIRECTIVE Pursuant to Machinery Directive 98 37 CE the installer who motorises a door or gate has the same obligations as the manufacture...

Page 13: ...4M Spring 5 UPC Set of 10 red reflectors UP4MP Spring 3 5 UPAF Fixed bearing UPSN Articulated joint for UP4BC 4BL arms RHIPBG50 HIPBTA Border plug 3 INSTALLATION Unless otherwise specified all measure...

Page 14: ...system which supports the springs for safety purposes is constructed in order to have a stable position with arm completely open or completely closed even with the motor release Never use the motor f...

Page 15: ...ected For automatic closing by both motors proceed as follows make a jumper between 1 and 2 in both A and B set TC to the same value on both A and B RESTART Manual battery connection E B in standby st...

Page 16: ...press the RESTART button If the problem persists check battery and recharge if need be With adequate solar radiation the panels start charging the batteries and the electric panel latches on automatic...

Page 17: ...eld responsible for possible damage caused by improper erroneous or unresonable use Avoid operating in the proximity of the hinges or moving mechanical parts Do not enter the field of action of the mo...

Page 18: ...es L installateur doit fournir tous les renseignements concernant le fonctionement automatique manuel ou de secours de la porte ou du portail automatis s et remettre la notice d emploi l utilisateur...

Page 19: ...libre 4500 mm UPGR Herse aluminium L 2000 mm UP4M Ressort 5 UPC Serie de 10 bandes autocollantes UP4MP Ressort 3 5 reflechissantes rouges UPSN Articulation pour lisses UP4BC 4BL UPAF Appui fixe RHIPB...

Page 20: ...re ou tende vers le haut fig 6 Le syst me de leviers soutenant les ressorts pour des raisons de s curit est r alis a fin d obtenir une position stable lorsque le bras est compl tement ouvert ou compl...

Page 21: ...ouverture qu la fermeture R1 Pouss e sur les obstacles L armoire lectrique est quip e d un dispositif de s curit qui arr te le mouvement en cas d obstacle pendant la manoeuvre d ouverture et inverse...

Page 22: ...touche RESTART et si le probl me persiste v rifier et recharger les batteries Si l nergie solaire est suffisante les panneaux commencent charger les batteries et l armoire lectrique se branche automat...

Page 23: ...automatis s puissent tre actionn s involontairement En cas de panne ou de mauvais fonctionnement du produit d brancher l interrupteur de secteur ae s abstenir de toute tentative de r paration ou d in...

Page 24: ...jeder Anlage sind die technischen Daten des Torantriebs gut sichtbar anzubringen Vor dem Netzanschlu ist sicherzustellen da die Daten auf dem Typenschild mit denen des Stromversorgungsnetzes bereinst...

Page 25: ...P4M Feder 5 UPC Packung anz 10 Rote R ckstrahler UP4MP Feder 3 5 UPAF Festlager UPSN Gelenk f r UP4BC 4BL Arme RHIPBG50 HIPBTA Profile Stopfen 3 MONTAGE Alle angegebenen Ma e werden in mm ausgedr ckt...

Page 26: ...em Zubeh r ausbalanciert oder nach oben gerichtet ist Abb 6 Das Hebelsystem das die Feder zur Sicherheit st tzt ist so konstruiert da bei ganz ge ffnetem oder geschlossenem ArmauchbeientsperrtemMotore...

Page 27: ...en nicht miteinander verbunden werden Falls die automatische Schlie ung beider Automatisierungen gew nscht ist Br cken Sie 1 2 sowohl auf A als auch B Stellen Sie auf A und B dieselbe Zeit TC ein REST...

Page 28: ...kt werden Sollte das Problem fortbestehen m ssen die Batterien berpr ft und nachgeladen werden Wenn ausreichend Sonnenstrahlung zur Verf gung steht beginnen die Zellen mit dem Laden der Batterien und...

Page 29: ...ln oder der Antriebsteile aufzuhalten W hrend des ffnens und Schlie ens nicht den Arbeitsbereich des elektrisch angetriebenen Tors betreten Die Bewegung des elektrisch angetriebenen Tors nicht aufhalt...

Page 30: ...ento autom tico manual y de emergencia de la puerta o verja motorizadas y entregar al usuario del equipo las instrucciones para el uso Proveerse de brazaletes conductores anti staticos conectados a ti...

Page 31: ...ular 30x100 paso libre 4500 mm UPGR Fald n de aluminio L 2000 mm UP4M Resorte 5 UPC Serie de 10 cat ptricos rojos UP4MP Resorte 3 5 UPAF Apoyo fijo UPSN Desataro para brazo UP4BC 4BL RHIPBG50 HIPBTA C...

Page 32: ...accesorios instalados o con tendencia para abrir fig 6 Elsistemadepalancasquesujetanlosresortes pormotivosdeseguridad est fabricadodemaneraque aldesbloquearlo elbrazoquedeparadocuandoenposici ntotalm...

Page 33: ...puentear 1 2 tanto sobre A como sobre B programar el mismo tiempo TC sobre A y sobre B RESTART Introducci n manual de la bater a Tablero el ctrico en posici n de espera stand by Normalmente el tablero...

Page 34: ...o 30 3 o 30 4 presionar la tecla RESTART y si el problema persiste controlar y cargar de nuevo las bater as Silaenerg asolaressuficiente lospanelesinicianacargarlasbater asyeltableroel ctricoseconecta...

Page 35: ...o entrar en el radio de acci n de la puerta o verja motorizada durante su movimiento No oporse al movimiento de la puerta motorizada puede ser peligroso No sujetar la varilla de la barrera y no colgar...

Page 36: ...DITEC S p A Via Mons Banfi 3 21042 Caronno P lla VA Italy Tel 39 02 963911 Fax 39 02 9650314 www ditec it CARONNO P LLA VA QUARTO D ALTINO VE ISO 9001 Cert n 0957 0...

Reviews: