29
8. Installation of the unit
IMPORTANT
: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will
remain in view.
IMPORTANT
: whenever the opening in the wall made for the unit is not equipped for the connection to the electrical power sup-
ply, remember to make an adequate opening in the wall for the exit of the air conditioner's power supply cable.
The creation of this space is essential because at the end of installation a plate in ABS will be inserted in front of the unit to mask the
opening in the wall and if sufficient space has not been provided the power supply cable might keep the unit raised from the wall.
Insert the unit into the recess made in the wall and pass the condensate drainage hose along the air expulsion pipe and check the
stability of the air conditioner. Push the unit in towards the wall behind it (this operation can be made easier by inserting the rectan-
gular ABS plate supplied at the base of the opening).).
Rear grills
electric heating element
Power supply cable
air conditioner
condensate drain
Internal con-
densate draina-
ge pipe
9. Complete installation by assembling the ABS frame that
will mask the installation opening in the wall and then
insert a pad of 29+29 sound absorption matting between
the external frame and the plate (see Figure 11).
fig. 11
ABS frame
Sound absorption matting
Air pipe
Insulated air pipe
Summary of Contents for RDW 9RN