Device Features
Figure 2-6- CAN Connections & Bus Terminating
CAN
DEVICE
CANHI
CANLO
SHD
SHD
CANLO
CANHI
CAN
DEVICE
CAN
DEVICE
CANHI
CANLO
SHD
VersaGateway
ENABLE
TERMINATOR
ENABLE
TERMINATOR
NMEA
DEVICE
SHD
+EXT VDC
-EXT VDC
CANLO
CANHI
+ -
CANLO
CANHI
+ -
CAN PORT 1 JUMPER CONFIGURATIONS
CAN port 1 can be configured with multiple options including the choice of on-board power (standard) or external power (NMEA
Compliant) as well as the choice of external supply voltage (if configured for external power). These options are all configured using
on-board jumpers. Refer to Figure 1-5 for the location of the configuration jumpers. Refer to Figure 1-5 for CAN Port Jumpers (CP1,
CP2). Refer to Figure 2-7 for Pin 1 Locations of CP1 and CP2.
Both CP1 and CP2 Jumper blocks must be configured for CAN port 1 to be completely configured
.
CAN PORT 1 CONFIGURATION JUMPERS
Jumper ID
Shunt Installation
Description
CP1
Shunt installed Pins 1-2
CAN Port 1 NMEA Compliant, External 9-32VDC Powered
Shunt installed Pins 2-3
CAN Port 1 Non-NMEA Compliant, External 5VDC Powered
Shunts installed Pins 1-2 & 3-4
CAN Port 1 Non-NMEA Compliant, Internally Powered
CP2
Shunt installed Pins 1-2
CAN Port 1 Internally Powered
Shunt installed Pins 2-3
CAN Port 1 Externally Powered
PIN 1
Figure 2-7 - CP1 / CP2 Pin 1 Locations
PIN 1