TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE CORRECTIVE ACTION

Unit does not start 

when full of

condensate

1.  Power is not supplied 

to pump.

2. Pump impeller is    

    not turning.

1.  Take top of pump off of tank and move the float up by 

hand. The pump motor should turn on, the fan should be 

visibly spinning through the top of the deck cover, and the 

fan should be audible.

2.  Clear any blockage in impeller housing. If problem 

persists, motor is stuck. Return pump to place of 

purchase if under warranty.

Condensate is

overflowing from 

unit

1.  Power is not supplied 

to pump.

2.  Pump is in overflow 

condition.

3. Pump is not level.

 

4.  Outlet flow is blocked.

5.  Pump impeller is not 

turning.

1.  Take top of pump off of tank and move the float up by 

hand. The pump motor should turn on, the fan should be 

visibly spinning through the top of the deck cover, and the 

fan should be audible.

2.  The inlet flow to condensate pump is exceeding outlet 

flow. Check to ensure that pump safety switch (alarm 

circuit) is connected to appliance. The safety switch 

connection will shut off appliance in this condition.

3.  Check to ensure that pump is level. If pump is not level, 

it may not activate, causing water to overflow from tank. 

Place unit on a flat and level surface.

4.  Check outlet tubing to ensure that it is not kinked or 

blocked. Clear blocked tubing of slime and debris. Clean 

inlet and outlet piping.

5.  Clear any blockage in impeller housing. If problem 

persists, motor is stuck. Return pump to place of 

purchase if under warranty.

Pump will not

shut off

1. Outlet flow is   

    blocked.

1.  Check outlet tubing to ensure that it is not kinked or 

blocked. Clear blocked tubing of slime and debris. Clean 

inlet and outlet piping.

WARRANTY

All pumps manufactured by or for DiversiTech Corporation (the Company) 

and sold by the Company under the Asurity or DiversiTech brand are 

warranted to be free of defects in workmanship and materials for a period 

of 36 months from date of sale from the distributor to the contractor. The 

Company will credit, repair or replace, at its option, any Pump if deemed 

defective within this time period. All products returned to the Company must 

include a return authorization issued by the Company. The returned product 

should be suitably packaged and shipped prepaid from the point of ship-

ment to the point designated in the Company’s return authorization.
This warranty is a limited warranty and shall be in lieu of any other 

warranties, expressed or implied, including, but not limited to, any implied 

warranty of merchantability or fitness for a particular purpose. There are 

no other warranties that extend beyond the description of the face hereof. 

The liability of the Company arising out of its supply of said products, or 

their use shall not in any case exceed the cost of correcting defects in the 

products as set forth above. The Company shall not be liable for any costs 

or damage incurred by its customers in the removal or replacement of 

defective products from units in which the products have been assembled. 

In no event shall the company be liable for loss of profits, indirect, 

consequential, or incidental damages.

Summary of Contents for ASURITY PROCP-22S

Page 1: ...Installation Instructions Standard Applications Models PROCP 22S PROCP 22S 230 PROCP 22ST PROCP 22ST 230 Condensate Pump Pro...

Page 2: ...r birth defects or other reproductive harm Wash hands after handling this product CAUTION FLOOD RISK Personal injury or property damage can result from an inoperative pump If a flood has occurred DO N...

Page 3: ...ter from the appliance When water collected reaches sufficient level inside pump tank pump switches on and pumps water to a remote location for disposal When tank is sufficiently empty pump automatica...

Page 4: ...densate Pump 1 B Inlet Hole Covers 3 PROCP 22S PROCP 22ST PROCP 22S 230 PROCP 22ST 230 Rated Voltage 120 Volts 60Hz 220 Volts 60 Hz Rated Current Draw 1 9 Amps 1 0 Amps Head Height 22 ft maximum 22 ft...

Page 5: ...ndensate pump location 1B ATTACH TO WALL Attach condensate pump with screws 8 between mounting tabs OPTION REVERSE TOP IF NECESSARY Pump top may be rotated 180 to allow access to pump outlet or power...

Page 6: ...TLET TUBE CONNECTION Attach plastic tubing to check valve and secure with hose clamp Route tubing up and away from condensate pump avoid compressing or kinking tubing 1 2 3 8 Clear vinyl plastic tubin...

Page 7: ...ap should be used INLET COVERS 5 INSTALL INLET COVERS Insert inlet covers in remaining condensate pump inlet holes Inlet holes Orificios de entrada Inlet tubing Tuber a de entrada Inlet holes Orificio...

Page 8: ...uce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle This pump must be properly connected to power following the National Electric Code...

Page 9: ...ian 3 The modification meets code compliant requirements according to the local authority This modification does not void the factory warranty Final installations should always be inspected and approv...

Page 10: ...TENANCE AND DISASSEMBLY ALWAYS disconnect power before performing maintenance Pump and deck may be removed from tank by pushing tabs located on tank sides away from deck while lifting on pump cover Pe...

Page 11: ...s stuck Return pump to place of purchase if under warranty Pump will not shut off 1 Outlet flow is blocked 1 Check outlet tubing to ensure that it is not kinked or blocked Clear blocked tubing of slim...

Page 12: ...s despu s de manipular este producto PRECAUCI N RIESGO DE INUNDACI N Una bomba que no funcione puede producir lesiones personales o da os a la propiedad Si se produce una inundaci n NO camine en el re...

Page 13: ...o el tanque est lo suficientemente vac o la bomba se apaga autom ticamente La bomba tiene capacidad para elevar el agua hasta 6 10 m y est equipada con una v lvula de control que evita que el agua se...

Page 14: ...ROCP 22S PROCP 22ST PROCP 22S 230 PROCP 22ST 230 Voltaje calificado 120 voltios 60 Hz 220 voltios 60 Hz Consumo calificado de corriente 1 9 amperios 1 0 amperios Alto de cabezales M ximo de 4 87 m M x...

Page 15: ...Fije la bomba de condensaci n con los tornillos 20 32 cm entre las leng etas de montaje OPCI N 2 INVIERTA LA PARTE SUPERIOR SI FUERA NECESARIO La parte superior de la bomba puede girar 180 para permi...

Page 16: ...ALIDA Fije el tubo de pl stico para verificar la v lvula y asegurarlo con la abrazadera para manguera Gu e la tuber a hacia arriba y lejos de la bomba de condensaci n Evite comprimir o retorcer la tub...

Page 17: ...ber usar una trampa pl stica CUBIERTA 5 INSTALE LAS CUBIERTAS DE ENTRADA Coloque las cubiertas de entrada en los orificios de entrada restantes de la bomba de condensaci n Inlet holes Orificios de ent...

Page 18: ...la garant a y podr a provocar una descarga el ctrica fatal Y W G R Y W G R A 6 SYSTEM T STAT Com Run OVERFLOW SWITCH 24V 1A Max Shut Down Circuit Shut Down Circuit Overflow Switch is normally closed...

Page 19: ...ectado a tierra Esta bomba se debe conectar a la alimentaci n de forma adecuada siguiendo el C digo el ctrico nacional NEC por sus siglas en ingl s Si no sigue estas advertencias anular la garant a y...

Page 20: ...e la parte superior de la bomba Aseg rese de que el agua est bombeando por el tubo de salida 2 PROBANDO EL INTERRUPTOR DE DESBORDAMIENTO SI EST CONECTADO Retire la parte superior de la bomba del tanqu...

Page 21: ...vanta la cubierta de la bomba Inspeccione peri dicamente el tanque de la bomba de condensaci n para asegurarse de que est libre de suciedad o lodo acumulados NO use limpiadores a base de solventes Lim...

Page 22: ...be encenderse el ventilador debe girar visiblemente a trav s de la parte superior de la cubierta y el ventilador debe escucharse 2 El flujo de entrada de la bomba de condensaci n excede el flujo de sa...

Page 23: ...v o al punto designado en la autorizaci n de devoluci n de la Compa a Esta garant a es limitada y reemplazar cualquier otra garant a expresa o impl cita e incluye pero no se limita a cualquier otra ga...

Page 24: ...Diversitech Corporation Duluth GA 30097 800 995 2222 DOC172636 AsurityTM is a registered trademark of DiversiTech Corporation 2020 DiversiTech Corporation...

Reviews: