8.7.3 Electrical connections
The normal set of electrical components that may be supplied with the Typhoon Central Dust Collector comprise of the following:
The exhauster motor, the exhauster motor starter, the solenoid inlet valve, the water level sensor, and the control box. Each electrical
connection shall be made in accordance with the appropriate wiring schematic enclosed with the Typhoon Central Dust Collector instruction
packet. Also note the following:
• Secure to body with hose clamps
• Mount the water level sensor on the lid of the water level box
• Connect the water level sensor leads to black, white, and green wires
in accordance with wiring diagram
• Run water level sensor wire cable to the control box and see
section 8.8
for electrical connection
• Secure the electrical cable to body with cable clamps
• Connect a ¾” hose from the water level box to the main body outlet to allow pressure equalization.
• Control box: The control box is mounted to the middle section and will connect to each of the
other electrical components.
• Exhauster motor: The motor nameplate will show the connection hook-up of the motor leads. The
motor leads will already be connected to the motor cable, which will need to be connected to the
control box according to the wiring diagram.
Mount the control box to the middle section via the supplied mounting bracket. Install the bracket arms to the upper and lower
flanges and bolt in place.