32
ALL BILLS ARE REJECTED
All bills are rejected.
Main Power OFF /
Disconnected.
Apply power
Blown Fuse
Check fuses and
replace if
necessary.
Machine is Out Of
Service.
List errors to determine
cause of Out Of Service.
Refer to pg. 13 for error
explanations.
Loose connection.
Check cable at
bill validator and
controller board.
Coin mechanism low on
coins.
Fill coin tubes.
Bill path obstructed /
dirty.
Clear / clean
path.
Wrong option switch
settings.
Reset.
Incompatible bill
validator.
Replace.
Defective bill validator.
Replace.
Defective controller
board.
Replace.
Summary of Contents for DN 2145
Page 1: ......
Page 40: ...40 DN55 VENDER NON ENERGY STAR Beverage Max Diagram 9 Column ...
Page 41: ...41 DN55 ENERGY STAR VENDER Beverage Max Diagram 9 Column ...
Page 42: ...42 DN35 VENDER NON ENERGY STAR Beverage Max Diagram 6 Column ...
Page 43: ...43 DN35 ENERGY STAR VENDER Beverage Max Diagram 6 Column ...
Page 44: ...44 DN55 35 Compressor Wiring Diagram ...
Page 45: ...45 DN55 DN2145 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 3 ...
Page 46: ...46 DN55 2145 AC DISTRIBUTION BOX SCHEMATIC EXPORT FIGURE 4 ...
Page 47: ...47 DN35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 5 ...
Page 48: ...48 DN55 35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC ENERGY STAR FIGURE 6 ...
Page 50: ...50 ECC SYSTEM SCHEMATIC RIGHT SIDE MDB SAMPLE ...
Page 51: ...51 ECC SYSTEM SCHEMATIC LEFT SIDE SAMPLE ...
Page 52: ...52 ASSY AC BOX DOMESTIC ...
Page 53: ...53 ASSY AC BOX DOMESTIC T8 Electronic ...
Page 54: ...54 ASSY AC BOX CE GS EXPORT ...
Page 56: ...56 MACHINE FRONT VIEW 1 14 6 7 3 5 2 4A 4B 4C 13 10 11 15 8 ...
Page 58: ...58 MACHINE FRONT VIEW 2 7 14 3 13 2 1E 1C 11 1B 6 10 11 1G 4 17 ...
Page 60: ...60 CABINET DETAIL 14 3 9 12 3 1 2 7 8 8B 7 10 11 11 13 5 6 ...
Page 64: ...64 SERVICE DOOR 1 1 5 6 7 8 6F 6J 3 6A 7 ...
Page 66: ...66 SERVICE DOOR 2 15 6 5 4 1 2 6 17 20 8 19 21 9 11 12 4 14 18 ...
Page 68: ...68 SERVICE DOOR 3 12 17 2 20 7 5 13 19 14 15 11 4 10 9 8 ...
Page 70: ...70 TALL GATE TRAY DETAIL 1 8 9 8 13 15 15 14A 14C 14B 18 16 14B 12 ...
Page 75: ...75 EXPORT AC DISTRIBUTION BOX 220 VAC 4 ...
Page 77: ...77 REFRIGERATION UNIT DN 55 35 FIN TUBE CONDENSER 19 11 10 13 18 9 1 22 15 13 16 6 5 2 8 17 ...
Page 79: ...79 REFRIGERATION UNIT TECUMSEH DN 5500 DN 5400 DN 2145 ROLL UP CONDENSER ...
Page 82: ...82 HARNESSES 1 2 3 7 4A 6 4B 24 22 5A 5B 5C 9 10A ...
Page 85: ...85 SCREWS NUTS ...