PROGRAMMING
P-SERIES
Page 13 of 76
MV – MULTI VEND
This function, when turned on, allows credit to be retained after a vend so the customer can vend from
another selection. (i.e..50 vend price, put in $1.00, push a select button and vends, .50 still shows on the
display, push a second select button and vends). Credit is cancelled after 5 minutes of inactivity. There
is unlimited acceptance. If a customer wants their credit (money) back, the coin return lever must be
pressed. To show the current “Multi Vend” condition, press select button 1 and the display will show the
current setting. Press and hold button 1 to toggle “Multi Vend” between “On” and “Off”.
Press and hold select buttons 1 & 2 simultaneously to move to “Return”.
RTN - RETURN
Press and hold button 1 to return to “Cash”.
USER
This function is used to configure the vender to operate in a fashion best suited for the vender location. To move
to “Diagnostics”(DIAG), press & hold select buttons 1 & 2 simultaneously, to enter the User Menu sub-menus
press select button1. The following are sub-menus of the User Menu: Space To Sales(STS), Column(CL), Time,
Language(LANG), Electronic Counter(ECNT), Limited Access(LIM), Secondary Price(SEC), Environmental
Controls(ECTL), Light(LT), Refrigeration(RFRG), Free Vend(FREE), Override(OVER), Sales Message(SSM),
Recharge(R-CH), and Return(RTN). The “Column” sub-menu prompt will only be available in machines with DC
motors.
STS – SPACE TO SALES
To view the space to sales condition, press select button 1 and display will show (SEL 1) “Selection 1”.
Alternating with columns assigned to that select button. Press select buttons 1 & 2 simultaneously to
scroll through the available select buttons to view columns assigned and “Return”.
To change space to sales
Press select button 1 at the “SEL #” prompt (CL## #)(column edit routine) will be displayed,
where the ## is the column to be added or deleted to the select button and the third # is “0” for
not assigned or “1” for assigned to that selection. Press select button 1 with “CL ## #” on the
display to toggle between “CL ## 0” and “CL ## 1”. With the setting you wish to use showing on
the display, press select buttons 1 & 2 to scroll to next columns to add/delete columns. Press
select button 1 at the “Return” prompt when selecting columns to enable, will return to “SEL #”.
Press select button 1 at the “RTN” prompt when choosing what selection to set for Space to
Sales, will return to “STS”.
Note: You must be in the “Selection” prompt to get to the “Return” mode that goes back to “Space
To Sales”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
CL- Column This prompt only appears on machines with DC motors.
Select this prompt to set column depth, package type and vend angles if the package type is custom. This
will scroll through the list of columns 1--- 9, “ALL” or “Return”(RTN) to select what column(s) will have its
settings changed. Pressing button 1 will display “Column # ”(CL #) where # represents the column
number.
Pressing select buttons 1 & 2 simultaneously will scroll through the columns.
Press select button 1 to scroll to “Package”
“Pack” Package
- is the next prompt. Press select buttons 1 & 2 simultaneously after entry into
this sub-menu will toggle between “Pack” and “RTN”. Pressing select button 1 when “Pack” is
displayed allows setting the package type for the column selected in the column prompt. Pressing
select button 1 will show current package setting. (i.e.1, 2, 3, …, “CUST” (CUSTOM), and “RTN”
(RETURN). Press select buttons 1 & 2 simultaneously to scroll through the package settings.
Summary of Contents for DN552P-7
Page 32: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 32 of 76 ALL BILLS ARE REJECTED...
Page 33: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 33 of 76 INCORRECT CHANGE DISPENSED...
Page 34: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 34 of 76 SELECTION WILL NOT VEND...
Page 36: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 36 of 76 COMPRESSOR WILL NOT START...
Page 37: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 37 of 76 MACHINE NOT COOLING...
Page 39: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 39 of 76 LIGHTS ARE NOT ON...
Page 41: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 41 of 76 SOLD OUT...
Page 42: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 42 of 76 THE DISPLAY IS DEAD...
Page 43: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 43 of 76 CAN T READ THE DISPLAY...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 44 of 76 7 Select 6 Column...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 45 of 76 Refrigeration Circuit Diagrams...
Page 46: ...PARTS LIST P SERIES Page 46 of 76 MAIN DOOR EXTERIOR...
Page 47: ...PARTS LIST P SERIES Page 47 of 76 MAIN DOOR EXTERIOR...
Page 50: ...PARTS LIST P SERIES Page 50 of 76...
Page 55: ...PARTS LIST P SERIES Page 55 of 76 INNER DOOR 6 7 10 4 2 9 3 5 1 8...
Page 66: ...PARTS LIST P SERIES Page 66 of 76 EVAPORATOR FAN ASSEMBLY 4B 3 2 7 4A 9 5 6 21 22 23 24...
Page 72: ...PARTS LIST P SERIES Page 72 of 76 SCREWS NUTS...
Page 74: ...PARTS LIST P SERIES Page 74 of 76 WASHERS BOLTS MISC HARDWARE...