PROGRAMMING
P-SERIES
Page 20 of 76
RFRG - REFRIGERATION
This function is used to electronically control the refrigeration operations of the vender. . To enter the sub-
menu press select button 1. The following are sub-menus of the Refrigeration Menu: (TEMP)
“Temperature”, (C-F) “Celsius or Fahrenheit“, (DSP) “Display”, “Days”, (STRT) “Start”, “Stop”, (S-T)
“Storage Temperature”, (S-E) “Storage Enabled”, and (RTN) “Return”. To move to (FREE) Free Vend,
press & hold select buttons 1 & 2 simultaneously.
Press select button 1 will enter “Temperature”.
TEMP - Temperature
(Default Temperature 35
0
F/15
0
C)
This function is used to set the average product temperature for initial pull down and reload
recovery.
Press select button 1 and “tt.tx” will show on the display where x is F (Fahrenheit) or C
(Celsius) and tt.t is the degrees.
Press and hold select button 1 to increase or decrease the number by 1F or 0.5C. Release
select button with the display showing the temperature you wish to use and display will
return to “TEMP”.
Press select buttons 1 & 2 to scroll to “C” or “F”.
(C-F) - Celsius or Fahrenheit
This function is used to set the degree reading to (F) Fahrenheit or (C) Celsius.
Press select button 1 and the current setting will show on the display. Press and hold
select button 1 to toggle between F and C. Release the select button with the display
showing the setting you wish to use and display will return to “C” or “F”.
Press select buttons 1 & 2 to scroll to “DSP”.
(DSP) - Display
This function is used to enable the Temperature to be displayed following the “Ice Cold Drink”
message. “SSM” “
Sales Message” must also be set to On for the temperature to be
displayed
.
Press select button 1 and “DSP” will show on the display. Press select button 1 and the current
setting will be displayed (On or Off). Press and hold select button 1 to
toggle between “On” and “Off”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Days
This function is used to set the days of the week to use Temperature Setting Routine.
Day of Week:
(SUN) Sunday
(WED) Wednesday
(SAT) Saturday
(RTN)
Return (RTN)
(MON) Monday
(THUR) Thursday
(ALL) All Days
(TUE) Tuesday
(FRI)
Friday
(NONE) No Days
Press select button 1 and “Monday #” will show on the display, where # is “0” (disable) or“1”
(enable). Press and hold select button 1 to toggle between “0” and “1”. Release the select button
with the display showing the setting you wish to use. Press select buttons 1 & 2 simultaneously
to scroll through all available days, “All Days”(ALL), “No Days”(NONE), and “Return”(RTN).
Press select button 1 at the “Return” prompt returns to “Days”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Start (STRT)
This function is used to set the hours and minutes for storage temperature to become active.
Press select button 1 and the current four-digit hour and minute setting will be displayed (24 hour)
Press & hold select button 1: Set Hours
Press & hold select button 2: Set Minutes
Press select buttons 1 & 2 simultaneously to move to the next item on the menu.
Summary of Contents for DN552P-7
Page 32: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 32 of 76 ALL BILLS ARE REJECTED...
Page 33: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 33 of 76 INCORRECT CHANGE DISPENSED...
Page 34: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 34 of 76 SELECTION WILL NOT VEND...
Page 36: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 36 of 76 COMPRESSOR WILL NOT START...
Page 37: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 37 of 76 MACHINE NOT COOLING...
Page 39: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 39 of 76 LIGHTS ARE NOT ON...
Page 41: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 41 of 76 SOLD OUT...
Page 42: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 42 of 76 THE DISPLAY IS DEAD...
Page 43: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 43 of 76 CAN T READ THE DISPLAY...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 44 of 76 7 Select 6 Column...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 45 of 76 Refrigeration Circuit Diagrams...
Page 46: ...PARTS LIST P SERIES Page 46 of 76 MAIN DOOR EXTERIOR...
Page 47: ...PARTS LIST P SERIES Page 47 of 76 MAIN DOOR EXTERIOR...
Page 50: ...PARTS LIST P SERIES Page 50 of 76...
Page 55: ...PARTS LIST P SERIES Page 55 of 76 INNER DOOR 6 7 10 4 2 9 3 5 1 8...
Page 66: ...PARTS LIST P SERIES Page 66 of 76 EVAPORATOR FAN ASSEMBLY 4B 3 2 7 4A 9 5 6 21 22 23 24...
Page 72: ...PARTS LIST P SERIES Page 72 of 76 SCREWS NUTS...
Page 74: ...PARTS LIST P SERIES Page 74 of 76 WASHERS BOLTS MISC HARDWARE...