INSTALLATION & SETUP
16
Stop
This function is used to set the hours and minutes for storage temperature to become inactive.
Press select button 1 and the current four-digit hour and minute setting will be displayed (24hour).
Press & hold select button 1: Set Hours
Press & hold select button 2: Set Minutes
Press select buttons 1 & 2 simultaneously to move to the next item on the menu.
Storage Temperature
(Default Temperature 60
0
F/ 16
0
C)
This function is used to set the temperature for product storage. Press select button 1 and “tt.tx”
will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is the degrees.
Press and hold select button 1 to increase or decrease the number by 1 F or 0.5 C. Release
select button with the display showing the temperature you wish to use and display will return to
“Storage Temperature”
Press select buttons 1 and 2 simultaneously to scroll to “Storage Enabled”
Storage Enabled
This function is used to enable the storage setting to go in affect.
Press select button 1 and the current setting will be displayed (On or Off).
Press and hold select button to toggle between ”On or Off”.
Release the select button showing the setting you wish to use and display will return to “Storage
Enabled”
Press select buttons 1 & 2 to scroll to “Return”
Press select button 1 at “Return” to scroll to “Refrigeration”
Press select buttons 1 & 2 simultaneously to scroll to next item on the menu.
Free Vend
This function is used to set the Free Vend option. Note: For free vend to become active a free vend
switch must be connected to controller on free vend switch connector. Press select button 1 and “Enable”
will show on Display.
Enable
This function is used to allow the free vend to go in affect.
Press select button 1 and the current setting will be displayed (On or Off).
Press and hold select button 1 to toggle between “ On or Off”.
Release the select button showing the setting you wish to use and the display will return to
“Enable”.
Press select buttons 1 & 2 to scroll to “Display”
Display
This function is used to show the current number of free vends performed by the controller.
Press select button 1 and “#” will show on the display where “#” is the number of free vends
performed by the controller. Release the select button and display will return to “Display”
Press select buttons 1 and 2 simultaneously to scroll to “Reset”
Reset
This function is used to reset number of free vends to zero.
Press and hold select button 1 for 5 seconds to reset the number of free vends performed by the
controller to zero. Release the select button and the display will return to “Reset”.
Press select buttons 1 & 2 to scroll to “Return”.
Return
Press select button 1 to return to “Free Vend”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Summary of Contents for DNCB 501E
Page 26: ...MAJOR COMPONENT DESCRIPTION 25 HT2 UNIVERSAL CONTROLLER...
Page 42: ...WIRING DIAGRAMS AND SCHEMATICS 41 HT2...
Page 43: ...TROUBLESHOOTING 42 HT3...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS 43 Refrigeration Circuit Diagrams...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS 44...
Page 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 SELECT PANEL...
Page 55: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 54 T8 LIGHTING...
Page 59: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 58 INNER DOOR...
Page 71: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 70 CABINET INTERIOR...
Page 81: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 80 SCREWS NUTS...