INSTALLATION & SETUP
18
Motors
Use this test to run any motor in the stack. Press select button 1and “Motor 1” will show on the display.
Use the following select buttons to run this test.
Press Select Buttons 1&2: Press until desired motor # to run or “Return” is shown on the display.
Press Select Button 1: Press to run the selected motor. The display will show “Vend” and the
selected motor will run.
Coin mech
Use this test to check coin mech, coin chute, and the coin mech payout systems. Insert coins. The value
of the coins will be reflected on the display. Press select button 2 will exit the test and return any coins
inserted and return to “Coin mech”.
Press select buttons 1 & 2 simultaneously to move to the next item on the menu.
Note Acceptor
Use this test to check note acceptor. Insert a bill. Bill will be held in escrow. Press select button 2 to stack
the bill. Press select button 3 to return the bill. After the note is has been stacked or returned, the display
will return to “Note Acceptor”.
Press & hold select buttons simultaneously to move to the next item on the menu.
Display
Press select button 1 and the display segments will illuminate in a scrolling manner and return to
“Display”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Relay
Compressor #
This function allows you to test the relay electronic control of the compressor.
CAUTION: Disconnect power to the compressor before testing the compressor relay.
Failure to disconnect power to the compressor before testing the relay could
result in damage to the compressor.
Press select button 1 and the display will show “Compressor #”, where # is the state of the relay 0
= not activated or off; 1= activated or on. Press select button 1 to toggle the relay on and off.
Press select buttons 1 & 2 simultaneously to move to “Fan”.
Fan #
This function allows you to test the relay electronic control of the evaporator fan.
Press select button 1 and the display will show “Fan #” where # is state of the relay 0 = not
activated or off; 1 = activated or on. Press select button 1 to toggle the relay on and off.
Press select buttons 1 & 2 simultaneously to scroll to “Light”.
Light #
This function allows you to test the relay electronic control of the lights.
Press select button 1 and the display will show “Light #”, where # is the state of the relay 0 = not
activated or off; 1 = activated or on. Press select button 1 to toggle the relay on and off.
Press select buttons 1 & 2 simultaneously to scroll to “Return”.
Press select button 1 to return to “Relay”.
Return
Press & hold select buttons 1 & 2 simultaneously to scroll to “Return”.
Press select button 1 to return to “Diagnostics”.
Press and hold select buttons 1 & 2 simultaneously to scroll to “Auto Test”.
Summary of Contents for DNCB 501E
Page 26: ...MAJOR COMPONENT DESCRIPTION 25 HT2 UNIVERSAL CONTROLLER...
Page 42: ...WIRING DIAGRAMS AND SCHEMATICS 41 HT2...
Page 43: ...TROUBLESHOOTING 42 HT3...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS 43 Refrigeration Circuit Diagrams...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS 44...
Page 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 SELECT PANEL...
Page 55: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 54 T8 LIGHTING...
Page 59: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 58 INNER DOOR...
Page 71: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 70 CABINET INTERIOR...
Page 81: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 80 SCREWS NUTS...