TROUBLESHOOTING
34
MACHINE NOT COOLING
Machine not cooling.
Dirty or clogged
condenser.
Clean.
Restricted airflow.
Check rear of vender for
obstructions. Ensure rear of
cabinet is at least 3.25" (82.6 mm)
from wall.
Faulty product seal.
Replace.
Condenser fan or
evaporator fan not
running.
Check blade for
obstruction.
Check fan
circuit.
Evaporator is iced up.
Check for air
leaks or clogged
condensate
drain line.
Faulty Temp Sensor or
control.
Replace.