MAINTENANCE
Dixon-
39
Replacing Air Filter
The engine is equipped with a replaceable, high
density paper air cleaner element and an oiled, foam
precleaner which surrounds the paper element.
Check the air cleaner daily or before starting the
engine. Check for a buildup of dirt and debris around
the air cleaner system. Keep this area clean. Also
check for loose or damaged components. Replace all
bent or damaged air cleaner components.
IMPORTANT INFORMATION
Operating the engine with loose or
damaged air cleaner components could
allow unfiltered air into the engine causing
premature wear and failure.
Air Filter
If the engine seems weak or runs unevenly, the air
filter may be clogged. If running with a dirty air filter,
the spark plugs can become fouled.
For this reason, it is important to replace the air filter
regularly (see the heading Maintenance Schedule for
the proper service interval).
WARNING!
The engine and the exhaust
system become very hot during
operation. Risk for burns if
touched.
Allow engine and exhaust system
to cool at least two (2) minutes.
IMPORTANT INFORMATION
Do not use compressed air to clean the air
filter.
Do not wash the paper filter.
Do not oil the paper filter.
Do not tap filter to clean this could cause
damage to the sealing.
Servicing Precleaner
Wash and re-oil the precleaner every
25 hours
of
operation (more often under extremely dusty or dirty
conditions). Replace the precleaner
annually, or every
100 hours.
Open the door on the blower housing
1.
to access the air cleaner element and
precleaner.
Unhook the latch and remove the precleaner
2.
from the air cleaner element, or remove as
an assembly for servicing. Make sure the
base and the sealing area is clean before
reassembly is performed.
Wash the precleaner in warm water with
3.
detergent. Rinse the precleaner thoroughly
until all traces of detergent are eliminated.
Squeeze out excess water (do not wring).
Allow the precleaner to air dry.
Saturate the precleaner with new engine oil.
4.
Squeeze out all excess oil.
Reinstall the precleaner over the paper
5.
element and secure with the latch.
Close and latch the door.
6.
Servicing Paper Element
Check the paper element
every 50 hours
of operation,
(more often under extremely dusty or dirty conditions).
Clean or replace the element as necessary. Replace
the air cleaner element
annually, or every 100 hours.
Open the door on the blower housing to
1.
access the air cleaner element.
Unhook the latch and remove the air cleaner
2.
element and precleaner.
Remove the precleaner (if so equipped) from
3.
the paper element. Service the precleaner as
described in Precleaner Service.
Gently tap the paper element to dislodge
4.
dirt.
Do not wash the paper element or
use pressurized air,
as this will damage the
element. Replace a dirty, bent, or damaged
element with a new one. Handle the new
element carefully; do not use if the sealing
surfaces are bent or damaged.
Clean the air cleaner base as required and
5.
check condition.
Reinstall the precleaner over the paper air
6.
cleaner element and install on the base.
Secure with the latch.
Close and latch the door.
7.
Summary of Contents for 968999724
Page 2: ...2008 HTC All rights reserved Beatrice NE Printed in U S A...
Page 70: ......
Page 71: ......
Page 72: ...P N 539 132404 R02 04 01 08...