maIntenanCe
35
Battery
Your mower is equipped with a maintenance free
battery that does not need servicing. However,
periodic charging of the battery with an automotive
type battery charger will extend its life.
Keep battery and terminals clean.
•
Keep battery bolts tight.
•
Recharge at 6-10 amperes for 1 hour
•
To clean battery and terminals
Corrosion and dirt on the battery and terminals can
cause the battery to “leak” power.
Open the terminal access doors.
1.
Remove the red terminal guard.
2.
Disconnect BLACK battery cable first, then the
3.
RED battery cable and remove the battery from
the machine.
Rinse the battery with plain water and dry.
4.
Clean terminals and battery cable ends with wire
5.
brush until shiny.
Coat terminals with grease or petroleum jelly
6.
Reinstall battery.
7.
Replacing battery
1. Lift seat and rotate forward.
2. Remove the terminal guard.
3. Using two ½" wrenches disconnect BLACK battery
cable then RED battery cable.
4. Unscrew the knob and remove battery hold down.
5. Carefully remove the battery from the mower.
6. Install new battery with terminals in the same
position as the old battery.
7. Reinstall battery hold down.
8. First connect RED battery cable to positive (+)
battery terminal with hex bolt and hex nut.
9. Connect BLACK grounding cable to negative (-)
battery terminal with remaining hex bolt and hex
nut.
10. Fit the terminal guard.
11. Lower seat.
IMPORTANT INFORMATION
Do not attempt to open or remove caps or
covers. Adding or checking level of electrolyte
is not necessary.
Always use two wrenches for the terminal
screws.
8050-109
Battery cleaning and installation
WARNING!
Do not short battery terminals by
allowing a wrench or any other object
to contact both terminals at the same
time. Before connecting battery, remove
metal bracelets, wristwatch bands,
rings, etc.
Positive terminal must be connected
first to prevent sparks from accidental
grounding.
Always use protective glasses when
handling the battery.
stanDaRD
batteRy
state
oF
CHaRGe
appRoXImate batteRy CHaRGInG tIme*
to FUll CHaRGe at 80
o
F / 27
o
C
maximum Rate at:
50 amps
30 amps
20 amps
10 amps
12.6V
100%
- FUll CHaRGe -
12.4V
75%
20 min.
35 min.
48 min.
90 min.
12.2V
50%
45 min.
75 min.
95 min.
180 min.
12.0V
25%
65 min.
115 min.
145 min.
280 min.
11.8V
0%
85 min.
150 min.
195 min.
370 min.
*Charging time depends on battery capacity,
condition, age, temperature and efficiency of charger
Summary of Contents for SPDZTR 30 BF
Page 47: ...schematics 47 8050 050...
Page 57: ...57 SERVICE JOURNAL Action Date mtr reading stamp sign...
Page 58: ...58 SERVICE JOURNAL Action Date mtr reading stamp sign...
Page 59: ......
Page 60: ...P N 115 161527R2 09 25 09...