35
CARE AND MAINTENANCE
HYDROSTAT DRIVE BELT
REPLACEMENT PROCEDURE:
To install hydrostat pump drive belt:
1.
Rotate the spring loaded take-up idler towards
the left hand hydro pump.
2.
Install belt per diagram.
3.
Install double u-joint and tighten flange bolts
(tighten to 14 ft. lbs.).
4.
Install radiator and mounting hardware.
5.
Attach radiator hoses and refill cooling system.