27
CARE AND MAINTENANCE
HYDROSTAT DRIVE BELT REPLACEMENT PROCEDURE:
To remove hydrostat pump drive belt:
(The hydrostat pump drive is equipped with a spring loaded belt take-up).
1.
Raise seat.
2.
Drain radiator.
3.
Remove radiator mounting hardware and hoses.
4.
Remove radiator.
5.
Remove double u-joint flange bolts and remove double u-joint.
6.
Rotate the spring loaded take-up idler towards the left hand hydro pump to
provide belt slack for removal.
7.
Remove belt.
To install hydrostat pump drive belt:
1.
Rotate the spring loaded take-up idler towards the left hand hydro pump.
2.
Install belt per diagram.
3.
Install double u-joint and tighten flange bolts. (tighten to 14 ft. lbs).
4.
Install radiator and mounting hardware.
5.
Attach radiator hoses and refill cooling system.
HYDROSTATIC PUMPS:
Before each use, check to be sure that the cooling fins of the hydrostatic pumps are clean.
Excessive accumulation of oil, dirt, or trash may cause the pumps to overheat. NEVER
WASH ACROSS TOP OF RESERVOIR WITH WATER OR STEAM. Fill reservoir as
required per the maintenance schedule listed in this book.