1.2 Place Selection
• The boiler cannot be mounted to
open balconies, closed ues or
closed ventilation.
• Maximum outdoor wind speed is
10 m/s.
• The product must have a 100
mm space on the sides and 200
mm on the bottom and top sides
to the walls or furniture surfaces
where it is mounted.
• There
must be a 100 mm space
to the front surface of the
product against hot contact.
• There should be 2 degree up
angle for ue connection.
• There must be at least a 500 mm
space from the product to
combustible surfaces and
equipment such as oven and
stove.
Figure A.2.1
C
H
E F
A
D
B
G
I
• The places must be selected
according to Figures A.2.1
and A.2.2
Minimum distances (cm)
A. Under windows
60 cm
B. Ventilation grills
60 cm
C. Rain systems
30 cm
D. Under balconies
30 cm
E. Window sills
40 cm
F. Ext. ventilation grills
60 cm
G. Vert. /Horiz. pipes
60 cm
H. Outer corners of bld.
30 cm
İ. Inner corners
100 cm
J. Floor
180 cm
K. Vertical distance between
two ues
150 cm
L. Horizontal distance between
two ues
100 cm
Wall Hang Bo lers User’s Installat on Manual
Figure A.2.2
Wall and Flue Connection Dimensions