Procedure 2: Extending the AC Power Cable (Original Plug Bracket)

1. Loosen the nut that seals the cable in the waterproof module, and remove the screw on 

the top of the module to open it.

2. Cut off the original female plug bracket. Remove the power cable and replace it with a 

longer one provided by yourself.

3.  Solder the original female plug bracket onto the new power cable. 

4.  Insert the female plug bracket into the waterproof module and tighten the screw. Tighten 

the nut to ensure a good seal between the cable and waterproof module.

Procedure 3: Converting to a DC Power Cable

Follow the procedure shown in the figure below to convert the power cable to a DC power cable.
The modification procedure is the same as that of Procedure 1 for extending an AC power cable, but different 
pins are required. Connect the cable wires to the DC negative and DC positive poles on the female plug 
bracket to use the cable as a DC power cable.

DC negative pole

DC positive pole

Summary of Contents for Aeroscope AS-F1800

Page 1: ...2020 10 Aeroscope AS F1800 V2 0 User Manual...

Page 2: ......

Page 3: ...uction 2 In the Box 3 Overview 3 Indicators 4 Function Descriptions 6 Basic Functions 6 Features 6 Operation and Maintenance 7 Installation 8 Lightning Protection 8 Step by Step Installation Guide 8 I...

Page 4: ...contractors of your affiliates which are companies or entities that you own that own you or that have the same owner or corporate parent as you You acknowledge and agree that a DJI do not help you co...

Page 5: ...r Connected to the metal bracket of the mounting device In the Box Aeroscope Processor 1 Female Power Connector 1 Dongle 2 1 RJ45 Connector 1 Power Cable 1 RJ45 Waterproof Case 1 Processor Mounting Br...

Page 6: ...update failed Solid on off Functioning abnormally Added two status when the firmware is updated to v03 00 00 23 or later Indicator Description Yellow and red blinking alternatively Wireless dialing i...

Page 7: ...formation capture indicator When the Aeroscope receives UAV information it can indicate the number of UAVs in the area 4 Indicator Description Green blinking UAV detected green LED blinking indicates...

Page 8: ...including firmware updating resetting status inquiry self testing parameter configuration and more Environmental spectrum detection Aeroscope can scan for environmental interference and provide a refe...

Page 9: ...reset when a recoverable software error appears and it will send a failure warning when there is an unrecoverable software error or hardware error Operation and Maintenance Modes Descriptions Online...

Page 10: ...the height of the protected object h is the height of the lightning rod hr is the rolling sphere radius It depends on the lightning density and the protected matter and is given in the following table...

Page 11: ...he antennas to the unit via the antenna cable a If using G8 directional antennas connect each antenna to one antenna port of the stationary unit with an antenna cable Note that two adjacent antennas s...

Page 12: ...ion between the stationary unit and the nearest available power outlet In such cases a qualified electrical engineer must extend the initial power cable to complete the connection 5 After powering on...

Page 13: ...ted If the certificate doesn t work or has expired you will need to import a new certificate manually To import a new certificate follow this procedure 1 Acquire the certificate files from DJI A singl...

Page 14: ...one provided by yourself 3 Solder the provided plug pins onto the neutral and live wires of the new power cable crimping pliers can also be used then plug the two pins into the female plug bracket pr...

Page 15: ...e new power cable 4 Insert the female plug bracket into the waterproof module and tighten the screw Tighten the nut to ensure a good seal between the cable and waterproof module Procedure 3 Converting...

Page 16: ...ew and washer on the waterproof module are securely tightened to fix the female plug bracket in place 2 After securing the female plug bracket in place make sure to tighten the nut The internal rubber...

Page 17: ...Part 15 Subpart B 2016 Electrical Specifications Power Consumption 5 Approx 70W Input 100 240 V 50 60 Hz 2 5 A Max Working Environment Operating Temperature 30 C to 50 C without solar radiation 30 C...

Page 18: ...ompliance Contactadres EU DJI GmbH Industriestrasse 12 97618 Niederlauer Germany Declara o de conformidade da UE A SZ DJI TECHNOLOGY CO LTD declara atrav s deste documento que este dispositivo est em...

Page 19: ...s content is subject to change Download the latest version from https www dji com aeroscope If you have any questions about this document please contact DJI by sending a message to DocSupport dji com...

Reviews: