Important Check-Up Items
1. Checking the fuel level: Fill up the fuel tank before operation to reduce the chance of an operation being
interrupted by a low fuel level.
2. Checking the engine oil level: Working with a low engine oil level will cause damage to the engine. When the
engine oil amount falls below the safety level, the built-in engine oil sensor will stop the engine from working.
Check the engine oil level before each operation to avoid the inconvenience caused by unexpected
flameout.
3. Checking the sponge filter element of the air filter: A dirty sponge filter element decreases the air entering
the electronic fuel injection unit, which reduces the generator performance.
Using the Generator
Activation
The generator must be activated before using for the first time. Connect the remote controller to the internet
first. Use a USB-C cable to connect to the USB-C connector of the generator and the USB-A connector of the
remote controller. Run the DJI Agras app on the remote controller and tap on the upper left corner of the
main interface to enter the charging device interface to activate the generator.
Starting the Generator
1. DO NOT connect to any electric devices before starting the generator.
2. Make sure the engine has been filled with engine oil and the fuel tank with no less than 1L fuel.
3. Connect the charging cable to an Intelligent Flight Battery that is powered off. Press and then press and
hold the power button on the battery to power on the battery. D12000iE Multifunctional Inverter Generator
can connect with a T40/T30/T20P Intelligent Flight Battery.
4. Move the engine switch to the Start position and hold for at least 3 seconds and then release. The engine
switch will return to the ON position and the generator will start automatically.
5. The generator starts to charge the battery. Each of the four LEDs of the battery blinks successively during
charging. Remove the battery when the four LEDs turn solid or off and connect another battery to charge.
• The battery must be powered off before connecting it to the generator.
• The generator automatically attempts to start a maximum of three times every time the engine switch is moved to
the Start position with an interval of five seconds between each start attempt. If the generator fails to start after three
automatic attempts or stops right after starting, connect it to the remote controller to see more information regarding
the malfunction.
• If there are any working electric devices connected to the AC outlet while charging the battery, the charging capacity
for the battery will decrease accordingly and the charging time will be extended.
Stopping the Generator
1. Turn off all connected electric devices.
2. Move the engine switch to the OFF position and the generator will stop running.
3. Disconnect all connected electric devices.