3.4. Use of the remote 

Activate the remote in the menu. Press and hold any key on the remote. The display flashes twice 
which means that the connection was successful. . The Remote has two buttons. Button A turns on 
the function, button B will turn off the function. The transmission is able to reach 50 meters. 
You can assign 5 remotes to every fog machine. 
If you use the remote the output volume corresponds to your settings for Volume Out. 
 

 

3.5. Fluid Sensor 

The Fluid Sensor controls when there is enough fluid left in the tank. You can disable this function:  
 

 

Press Function until the Display shows “Fluid Sensor On” 

 

Use the UP / DOWN keys to switch the Sensor on / off 

 

Please notice that running low on Fog will cause Damage to the machine. 

 

If the Sensor is activated and the fog level is low it will deactivate the pump in between 20 
seconds 

 

For resetting the fluid sensor there are two possibilities: 
 
1.  Press and hold ENTER. If the fluid is refilled, the sensor after 10s is reset. 
2.  In DMX mode you have to set channel 2 to at first to value 0 and then to a value >5. If the 

fluid is refilled, the sensor after 10s is reset. 

 
Important! If you do not use the machine for more than 15 days, please fill out some clean water 
instead of snow fluid in the tank and run the engine for a few minutes.  

 

 
 
 

 

 

Summary of Contents for DFZ-800

Page 1: ...Manual Fazer DFZ 800 ...

Page 2: ... 3 Control 5 3 1 Installation 5 3 2 Starting up the machine 5 3 3 Explanation of menu and display 5 3 3 1 Ready to snow 5 3 3 2 Interval 5 3 3 3 Duration 6 3 3 4 Amount of fog 6 3 3 5 Volume Out 6 3 3 6 Fan speed 6 3 3 7 Fluid Sensor 6 3 3 8 DMX Setup 7 3 3 9 Remote 7 3 3 10 Timer 7 3 3 11 Language 7 3 4 Use of the remote 8 3 5 Fluid Sensor 8 4 Explanation of the hardware 9 5 Technical data 10 ...

Page 3: ... power supply before opening the housing Instructions for a safe and efficient operation at and extreme temperature Only use the device in a place where no extreme temperatures will occur Do not keep it in a temperature bellow 32 F 0 C or exceeding 104 F 40 C Avoid exposing it to direct rays of the sun or near a heating appliance way from humidity water and dust Do not place the set in a location ...

Page 4: ...t cause damages to the pump as well as over heating of the heater Never drink the fog liquids If it is ingested connect with a doctor immediately If the fog liquids come in contact with skins or eyes rinse thoroughly with water Note please pay attention to all the warning labels and instructions printed on the exterior of the unit 2 Introduction Thank you for choosing the DJ Power Fazer DFZ 800 We...

Page 5: ... with the machine to a Power Supply according to the technical Data of the device Please make sure the device is sufficiently grounded Turn on the machine with the Power switch on the back The switch will light up red when the machine is on Power 3 3 Explanation of menu and display You will find 4 buttons on the machine MENU Press the button to scroll through the menu UP TIMER Press the button to ...

Page 6: ...function 3 3 5 Volume Out Press MENU until the Display shows Volume out Use the UP DOWN keys to set the Output between 1 100 This setup is required if you want to use the Volume function 3 3 6 Fan speed Press MENU until the Display shows Volume out Use the UP DOWN keys to set the fan speed between 1 100 This setup is required if you want to use the Volume function 3 3 7 Fluid Sensor Press MENU unt...

Page 7: ...tivated If you raise the value between 6 and 255 you will increase the snow output 3 3 9 Remote Press MENU until the Display shows Wireless Set Use the UP DOWN keys to choose between ON and OFF With OFF you activate the remote with OFF you deactivate the remote 3 3 10 Timer Press MENU until the Display shows Direct Timer Use the UP DOWN keys to choose between YES and NO With YES you activate the f...

Page 8: ...ble this function Press Function until the Display shows Fluid Sensor On Use the UP DOWN keys to switch the Sensor on off Please notice that running low on Fog will cause Damage to the machine If the Sensor is activated and the fog level is low it will deactivate the pump in between 20 seconds For resetting the fluid sensor there are two possibilities 1 Press and hold ENTER If the fluid is refille...

Page 9: ...2 4 Explanation of the hardware 1 Bracket 2 Safety hole 3 Nozzle 4 Quick connector 5 Fluid tank 6 Fluid tank baffle 7 Air vent 8 Antenna 9 LC Display 10 DMX 3pol 11 DMX 5pol 12 Power socket 13 Power switch ...

Page 10: ... consumption max 1150 W Fuse 8A 250 Connections Power in IEC XLR in out 3pol 5pol Controlling DMX512 Yes Number of channels 2 Technical data Ejection volume 226 m min Tank volume 3 5 l Fluid consumption 125min l Hardware Dimensions L B H 313 x 310 x 255 mm Weight 10 62 kg ...