background image

Nebelmaschine DF-V6C Art.No.: 115297 
 

4 / 13

 

2.

 

Intended use of the device 

This device was developed for professional use on stages, in discos, theatres 

etc.  The device is only approved for a connection up to 230 V 50/60 Hz 

alternating current and only for indoor use.  
Regular breaks during operation increase the lifetime of your device.  
Avoid convulsions or any form of forceful impact during the installation or the 

start up of the device.  
Take care that no cables are lying around. You would endanger your own 

safety and also the safety of a third party.  
It is not allowed to operate or store the device in an environment in which 

spray water or rain is expected.  Humidity or very high atmospheric humidity 

could reduce the isolation of the device and could cause deathly electric 

shocks.   
If using fog machine you have to ensure that the fog saturation of the room 

must allow a good visibility of at least 10m. 
Operate the device not during thunderstorms. Surge voltages could destroy 

the device. Unplug the power supply during thunderstorms.  
Surrounding objects or surfaces should not be in contact with the device.  
Make sure that during the installation and removal of the device the area 

below the place of installation is basically cordoned off. This also applies to 

implementation of service.  
Make familiar yourself with the functions of the device before start-up. People 

without the experience should not handle with the device. The most cause of 

functional disorder is inappropriate handling.  
Keep the device away from children and never operate it unattended.  
Never aim the nozzle on people a keep a distance from 50 cm to the nozzle. 

ATTENTION. The ejected fog is very hot! 
Keep a minimum distance of 50 cm to other objects.  
Use only the recommended, high quality water-based fluid from your dealer. 

Other fluids may cause damages. Do not use flammable additives, such as 

oil, gas, perfumes, etc. in your fluid.   
Never aim the nozzle on open fire or flammable objects.  
Make sure to top off the fluid in time. If the machine operated without fluid it 

can cause damages to the pump or the heating block.  Before top off the 

fluid please unplug the device from the power supply.  
Never drink the fluid. I fit does happen, please contact a doctor. If the fluid 

had contact with the eyes or mucous membranes, rinse immediately with 

water bodies.  
Operate the unit only in a horizontal position. 

Summary of Contents for DJV DF-V6C

Page 1: ...Nebelmaschine DF V6C USERS MANUAL ...

Page 2: ... 1 1 For safe and efficient operation 3 2 Intended use of the device 4 2 1 Electrical connections 5 3 Introduction 6 3 1 Item deliverd 6 3 2 Product description 6 4 Start up 7 4 1 Bedienung 7 4 1 1 Structure oft he menu 7 4 1 2 DMX chart 8 4 1 3 Wireless Remote 8 5 Technical data 9 ...

Page 3: ...rations always place the device on a firm ground Do not use chemicals for cleaning Use a clean and dry cleaning rag to remove dust Metal parts can be cleaned with a damped cleaning rag Before cleaning always unplug the device from the power supply If the device is not working properly If problems occur unplug the device from the power supply The user should not try to service the device independen...

Page 4: ...n contact with the device Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off This also applies to implementation of service Make familiar yourself with the functions of the device before start up People without the experience should not handle with the device The most cause of functional disorder is inappropriate hand...

Page 5: ...vice which differs from usages which are described in this manual can cause damages of the device In this case the warranty expires Additional you should notice that every different usage is related with dangers and can cause e g an electrical short fire electric shock or crash 2 1 Electrical connections Connect the fixture to the mains with the enclosed power cable and plug The earth has to be co...

Page 6: ...e read this manual carefully 3 1 Item deliverd 1x Fog machine DF V6C 1x Power cord IEC 1x Remote W 2 1x Receiver KT 1 Manual German English 3 2 Product description 1 Tank 2 Fluid tube 3 Handle 4 Fog button 5 Remote Wireless INPUT 6 XLR 3pol INPUT OUTPUT 7 Display Tank baffle 8 Nozzle 9 On Off Switch 10 Power supply IEC ...

Page 7: ...ce starts to heat up This process needs 4 min meanwhile the display shows HEAT 4 The heating process is finished The display shows Addr 4 1 Bedienung The operation can be made by the display manual by using the fog button or with remote MENU For call up the structure of the menu and set the DMX value UP Increase a value DOWN Dicrease a value ENTER STOP Confirm the setting 4 1 1 Structure oft he me...

Page 8: ...s Controller If you want to use several devices you can assign up to 4 devices to one remote by using the receivers 2 Dipswitches You can assign the receiver to different buttons or channels of the remote CH1 Dipswitch 1 On Dipswitch 2 4 Off CH2 Dipswitch 2 On Dipswitch 1 3 4 Off CH3 Dipswitch 3 On Dipswitch 1 2 4 Off CH4 Dipswitch 4 On Dipswitch 1 3 Off 2 Fog button 1 4 With the buttons CH1 CH4 y...

Page 9: ...wer consumption max 1350W Fuse 8A 250 V Heating power 1350 W Heating time 4 min Tank volume 2 5 Liter Output volume 850 m min Fluid consumption 100 149 ml min DMX512 Yes Number of DMX channels 1 Remote Yes Frequency oft he remote 433 MHz Power in IEC Dimensions 366 x 340 x 195 mm Weight 7 kg ...

Page 10: ...Nebelmaschine DF V6C Art No 115297 10 13 For your notes ...

Page 11: ...Nebelmaschine DF V6C Art No 115297 11 13 For your notes ...

Page 12: ...Nebelmaschine DF V6C Art No 115297 12 13 For your notes ...

Page 13: ...Nebelmaschine DF V6C Art No 115297 13 13 Importer B K Braun GmbH Im Stockmädle 27 D 76307 Karlsbad www bkbraun com info bkbraun com ...