Technical Specifications
AES Interface: (2)
Value
Note
Input Sample
Rate Converter (3)
Yes
Sample Rate Range
30 Hz – 100 kHz
Default Internal
48 kHz
Sample Rate
Synchronisation to external
sample rate (3)
Yes
Bit Resolution
24 Bit*)
Group Delay
1.75 mSec
Maximum
Passband Ripple
± 0.008 dB
THD+N (1 kHz, @ -1 dBFS)
103 dB
Typical
Dynamic Range
> 120 dB
Nominal Input Impedance
110 Ohm
Typical
Nominal Output Impedance
110 Ohm
Typical
28
MSD600M - Technical Reference Manual
(1) Measured with default condition at 48 kHz
internal sample rate. Used unless other is
mentioned.
(2) Measured with default condition at 48 kHz
internal sample rate and Sample Rate
Converter Enabled. Used unless other is
mentioned.
(3) The Input Sample Rate Converter function is
optional and can be bypassed. When doing so
attention must be taken to obtain synchroni-
sation between internal sample rate and
incoming sample rate. To do this the MSD unit
can be set to sync to the dedicated external
AES-3 sync input found in the utility connector.
*) Except digital input module 4 D/0 (=16 bit)
Summary of Contents for MSD600M
Page 7: ...MSD600M Technical Reference Manual 3...
Page 9: ...MSD600M Technical Reference Manual 5 See notes opposite page...
Page 11: ...MSD600M Technical Reference Manual 7...
Page 17: ...MSD600M Technical Reference Manual 13...
Page 23: ...MSD600M Technical Reference Manual 19...
Page 26: ...22 MSD600M Technical Reference Manual 10 The DK SCALE PC Software Program...
Page 33: ...MSD600M Technical Reference Manual 29...
Page 34: ...30 MSD600M Technical Reference Manual 13 Appendix B Mechanical Dimensions...
Page 35: ...MSD600M Technical Reference Manual 31...
Page 39: ...MSD600M Technical Reference Manual 35...