PT 5201
PTV
Operating Instructions
Operating Manual
Revision 2
6-7
Black Burst
Black Bursts are digitally generated under the VariTime
TM
system and is
independent in timing and generation of TV system (NTSC/PAL). The
VariTime
TM
system has a resolution of 0.15 ns and the timing range of 4
fields for NTSC and 8 fields for PAL.
System
:
The VariTime
TM
outputs are able to generate Black Burst in the following
formats:
PAL, PAL with ID, NTSC 7.5%,
and
NTSC 0%
Timing:
The VariTime™ unit is generating Black Burst with a resolution of 0.15 ns
and the timing range of 4 fields for NTSC and 8 fields for PAL.
Field, Line
and
Offset
can be modified within their relevant limits.
Edit of the number of Fields, Lines or Offset of ns to be advanced or
delayed can be done in 3 ways.
The modifications are typed directly in the edit boxes using number keys
and sign.
Incrementing or decrementing by the up/down buttons, or using the timing
bar.
Using the timing bar by grabbing the pointer with the mouse cursor and
moving it, for quick timing.
ScH-Phase
:
The VariTime
TM
system features adjustment of the ScH-Phase in the range
of ±180º in a resolution of 1º, operated using the up/down buttons, or typed
in directly.
6.5.2.3.3
SDI
The Video signal generator contains 23 basic patterns and signals, including Color Bars for the
respective TV systems. The video outputs deliver signals in two formats simultaneously, Analog
Composite (Video output) and SDI (SDI output) and has a common 4 or 8 fields timing range
with 37 ns resolution.
Analog and SDI Settings.
The SDI output features separate settings for embedded audio.
The Analog Composite output features ScH-Phase adjustment in 1º resolution.
Common settings:
System
The Video and SDI outputs generate patterns in
NTSC 7.5%
/525-lines,
NTSC 0%
/525lines and
PAL
/625lines systems.
One common system for both output at a time.
Timing:
The VariTime™ unit is generating Analog and Digital test signal outputs
with a resolution of 37 ns and the timing range of 4 fields for NTSC and 8
fields for PAL.
Field, Line
and
Offset
can be modified within their relevant limits.
Edit of the number of Fields, Lines or Offset of ns to be advanced or
delayed can be done in 3 ways.
The modifications are typed directly in the edit boxes using number keys