Operating Instructions
PTV
PT 5201
Revision 2
Operating Manual
6-8
and sign.
Incrementing or decrementing by the up/down buttons, or using the timing
bar.
Using the timing bar by grabbing the pointer with the mouse cursor and
moving it, for quick timing.
ScH-Phase
:
The VariTime
TM
system features adjustment of the ScH-Phase for the
analog test signal generator in the range of ±180º in a resolution of 1º,
operated using the up/down buttons, or typed in directly.
Pattern:
The video signal generator contains basic patterns and signals, including
Color Bars for the respective TV systems.
The list of signals consists of patterns for NTSC and PAL.
The video output signals are generated in two formats simultaneously,
Analog Composite (Video output) and SDI (SDI output).
Analog Settings:
The Analog Composite output features common timing and ScH-Phase
adjustment in 1º resolution.
SDI Settings:
The SDI output features common timing and separate settings for
embedded audio.
6.5.2.3.4
Audio
PT 5201 contains two independent audio generators, Analog Audio and AES/EBU digital audio
and a WordClock output (WCLK).
Due to common rear connectors, only one audio generator can be active at a time.
The AES/EBU generator features selectable sample rate, video reference lock, timing and a
number of tones and levels.
The Analog Audio generator features four tones in a large number of levels and right channel
identification.
Output
Selectable between Analog audio and digital AES/EBU.
Some of the fields in the menu may be grayed out, indicating that this
parameter is not valid for that format.
System
In Genlocked mode the AES/EBU generator locks to both video systems
and in Internal mode the audio generator is locked to the internal
reference.
Timing
Editing can be done in 3 ways.
The modifications are typed directly in the edit box using number keys.
Incrementing or decrementing by the up/down buttons, or using the timing
bar.
Using the timing bar by grabbing the pointer with the mouse cursor and
moving it, for quick timing.
Click Period
Selected by ticking off the appropriate field
Wordclock
Selectable between standard 48kHz and CD-audio sample frequency of
44.1kHz.
Tone
Selectable in the field between a number of frequencies.
Level
Selectable by using the scroll bar.
Summary of Contents for PT 5201 Compact VariTime
Page 6: ......
Page 20: ......
Page 40: ......
Page 56: ......