Commands Explanation.
PTV
PT 5201
Revision 2
Operating Manual
9-6
System
Description
PAL
PAL
PAL_ID
PAL with line 7 pulse
NTSC
NTSC with setup
JNTSC
NTSC no setup
Example:
OUTP:BB1:SYST PAL_ID
set system for BB output 1 to PAL with line 7 pulse
OUTP:BB1:SYST?
response:
PAL_ID
•
OUTPut:BB1:DELay
•
OUTPut:BB2:DELay
•
OUTPut:BB3:DELay
Command to set the delay of the three Black Burst output. The delay is defined by three
parameters
<Field>, <Line>,<HTime>
where
<Field>
sets the field offset,
<Line>
sets the line offset and
<HTime>
sets the
horizontal time in ns, i.e.
HTime(PAL) < 64000.0ns
HTime(NTSC) < 63492.1ns
It is not possible to select a delay outside the range of the selected system. See the table
below.
ANALOG
PAL, 625 lines
NTSC, 525 lines
Field
Line
Field
Line
-3
-0, .., -312
-
-
-2
-0, .., -311
-
-
-1
-0, .., -312
-1
-0, .., -262
-0
-0, .., -311
-0
-0, .., -261
+0
+0, .., +312
+0
+0, .., +262
+1
+0, .., +311
+1
+0, .., +261
+2
+0, .., +312
+2
+0
+3
+0, .., +311
-
-
+4
+0
-
-
Example:
OUTP:BB2:DEL -2,-4,-3245.2
set delay for BB output 2 to -2 field, -4 line & -3245.2ns
OUTP:BB2:DEL?
response:
-2,-004,-03245.2
•
OUTPut:BB1:SCHPhase
•
OUTPut:BB2:SCHPhase
•
OUTPut:BB3:SCHPhase
Command to set the ScH-Phase of the three Black Burst output. The ScH-Phase value must
be in the range
180 < ScH-Phase <= +180
Example: