Commands Explanation.
PTV
PT 5201
Revision 2
Operating Manual
9-8
HTime(NTSC) < 63492.1ns
It is not possible to select a delay outside the range of the selected system. See the table
below.
ANALOG
PAL, 625 lines
NTSC, 525 lines
Field
Line
Field
Line
-3
-0, .., -312
-
-
-2
-0, .., -311
-
-
-1
-0, .., -312
-1
-0, .., -262
-0
-0, .., -311
-0
-0, .., -261
+0
+0, .., +312
+0
+0, .., +262
+1
+0, .., +311
+1
+0, .., +261
+2
+0, .., +312
+2
+0
+3
+0, .., +311
-
-
+4
+0
-
-
Example:
OUTP:TSG:DEL -2,-4,-3245.2
set the delay for the SDI to -2 field, -4 line & 3245.2ns
OUTP:TSG:DEL?
response: -2,-004,-03245.2
•
OUTPut:TSGenerator:SCHPhase
Command to set the ScH-Phase of the SDI and Video outputs. The ScH-Phase value must be
in the range
180 < ScH-Phase <= +180
Example:
OUTP:TSG:SCHP -123
set the ScHPhase for -123deg
OUTP:TSG:SCHP?
response:
-123
•
OUTPut:TSGenerator:EMBaudio:SIGNal
Command to select the signal of the embedded audio in the SDI output. Refer to chapter 10
PT5201 Signals, for a description of the signals available.
Example:
OUTP:TSG:EMB:SIGN
set the embedded audio to OFF
OUTP:TSG:EMB:SIGN?
response:
OFF
•
OUTPut:TSGenerator?
Command to display the complete settings of the SDI and Video outputs. The response
contains seven fields:
<Pattern>,<System>,<Field>,<Line>,<HTime>,<ScHPhase>,<EmbAudio>
For an explanation of the response, see the commands:
OUTP:TSG:PATT
,
OUTP:TSG:SYST
,
OUTP:TSG:DEL
,
OUTP:TSG:SCHP
and
OUTP:TSG:EMB:SIGN.
Example:
OUTP:TSG?
response: CBEBU, PAL,+2,+123,+12345.5, -160,OFF