MSD/PT0600/200 - Technical Reference Manual
3
3. External
Synchronisation and
the Sample Rate
Converter (SRC)
The MSD has been designed to run on a fixed
internal sample rate at 48 kHz. However the user
can force the MSD to synchronise to any of the
available AES-3 Inputs.
• Please refer to section 18 for a complete set of
Synchronisation flowcharts for all supported
models
Since the unit’s internal sample rate also deter-
mines the AES output sample rate you can use the
external sync feature to synchronise the AES out-
puts sample rate. For details on how to set up the
MSD for external synchronisation please see sec-
tion 8.2.4.1 “SRC Bypass and external sync” in the
software manual. It is normal that professional
audio equipment such as mixing consoles are fitted
with sample rate converters in their AES input
stage. In these cases it is not necessary to syn-
chronise the AES output signal.
When an external sync source has been selected,
the MSD will sync to this input whether a valid sync
signal is present or not. If no valid signal is detec-
ted an error warning will be displayed on the MSD.
Even though the MSD is able to lock up to AES-3
signals at 96 kHz, an external AES-3 sync signal
with a sampling rate higher than 48 kHz should not
be used, as it may cause glitches in the audio
stream.
Synchronising to a lower sample rate than 48 kHz
(like 44.1 kHz) will not be a problem. It is however
Summary of Contents for PTO200C
Page 6: ...MSD PT0600 200 Technical Reference Manual...
Page 21: ...MSD PT0600 200 Technical Reference Manual 15 9 The DK SCALE PC Software Program...
Page 30: ...MSD PT0600 200 Technical Reference Manual 24 Rear view Chassis for the PT0600 200...
Page 69: ...MSD PT0600 200 Technical Reference Manual 63...
Page 73: ...MSD PT0600 200 Technical Reference Manual 67...