v.220629 | 19
DAILY START-UP PROCEDURE
1.
Set the Auto-On/Off lever to the Off position.
2.
Check the air compressor visually for any damage or obstruction.
3.
Close the drain valve.
4.
Connect the air hose to the quick connect socket on the regulator assembly by inserting the
quick connect plug on the air hose into the quick connect socket. The quick connect socket
collar will snap forward and lock the plug into place providing an airtight seal between the
socket and plug. To release the air hose push the collar back on the quick connect socket.
5.
Plug the power cord into the proper receptacle.
6.
Turn the Auto-on/Off lever to the On-Auto position and the compressor will start and build air
pressure in the tank to cut-out pressure and then shut off automatically.
7.
Adjust the regulator to a PSI setting that is needed for your application and be sure it is within
the safety standards required to perform the task. If using a pneumatic tool, the manufacturer
should have recommendations in the manual for the particular tool on operating PSI settings.
8.
The air compressor is now ready for use. The following inflation and cleaning accessories
packaged with this unit should only be operated at maximum pressure of 20-30 PSI: blow gun,
tapered nozzle, inflation needles, wire brush adapter, blow gun adapter.
DAILY SHUT-DOWN PROCEDURE
1.
Set the Auto-On/Off lever to the Off position.
2.
Unplug the power cord from the receptacle.
3.
Set the outlet pressure to zero on the regulator.
4.
Remove any air tools or accessories.
5.
Open the drain valve allowing air to bleed from the tank. After all of the air has bled from the
tank, close the drain valve to prevent debris buildup in the valve.
CAUTION!
When draining the tank, always use ear and eye protection. Drain the tank in a
suitable location; condensation will be present in most instances of draining.
WARNING! Water that remains in the tank during storage will corrode and weaken the air
tank, which could cause the tank to rupture. To avoid serious injury, be sure to drain the
tank after each use or daily.
STORAGE
1.
Turn the unit off and unplug the power cord from the receptacle.
2.
Remove all air hoses, accessories, and air tools from the air compressor.
3.
Perform the daily maintenance schedule.
4.
Open the drain valve to bleed all air from the tank.
5.
Close the drain valve.
6.
Store the air compressor in a clean and dry location.
ENGLISH
Summary of Contents for AC10G
Page 5: ...SECTION I SAFETY ...
Page 11: ...SECTION II INSTALLATION ...
Page 14: ...SECTION III OPERATION ...
Page 18: ...SECTION IV MAINTENANCE ...
Page 22: ...SECTION V PARTS SCHEMATICS ...
Page 25: ...v 220629 25 SCHEMATICS ENGLISH ...
Page 30: ...SECTION I SÉCURITÉ ...
Page 37: ...SECTION II INSTALLATION ...
Page 40: ...SECTION III FONCTIONNEMENT ...
Page 44: ...SECTION IV ENTRETIEN ...
Page 48: ...SECTION V PIÈCES ET SCHÉMAS ...
Page 51: ...v 220629 51 SCHÉMAS FRANÇAIS ...
Page 52: ......