Tightness Control of Part Connection
Ensure that all of the buttons are off on the product. Be sure that the gas is on. For
the control of the gas leak, rub a small amount of soap to the hose connector.
If the gas leak would be foaming at the soap. Please review this case, gas
connection again.
WARNING: Never use matches and lighters flame to check gas leak.
GAS CONVERSION
Burners in your hob can be operated by different gases by installing injectors suited
for gases required to be fired. Contact with the authorized service for your gas type
changes.
Injectors change should be carried out by the authorized service staff as follows;
Remove fire bars and burners by lifting them upward.
Remove injectors by turning counter-clockwise and reassemble new
injectors suited for gas types to be used.
(See Table 1)
Tighten injectors properly.
IMPORTANT: Tightening the injector too much causes to become worn
and occur gas leakage, for this reason do not force too much when you
make sure of tightening the injector adequately.
After installing the injectors, check the gas leakage by foam.
For this process, foam the bottom of injectors, push over the injector with your
finger so as to close the gas outlet and check whether bubbles occur in the
connection point of injector or not.