background image

Drive

 Arm

Linking Ar

m

Arm Assembly

Install the gate attachment 

bracket to the gate.

Lockpin

Lockpin

Retaining Ring

Spacing

Washers

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CAUTION

RED 24V    RE

D

BLK 115V WH

T

QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE”

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

115 VAC Connection

Battery Connection

1. Brown

2. Blue

3. Orange

4. Red

5. Yellow

6. Green

7. Green/Yellow

Operator

Cable

Loop Wires

Coaxial Cable Antenna

(Not Supplied)

Alarm

Reset

Com

Com

4 Open Input

5 Open Input

N.O.

Relay

24V

Chassis

Ground

Mounting

Hole

Radio Receiver

Tip: 

It is recommended 

that a surge suppressor 

be installed on the high 

voltage power lines.

DANGER

HIGH VOLTAGE!

Loop Detectors

Board Adjustments

C

C

A

B

F

F

C

C

E

E

Do not connect the battery plug to the 

circuit board until power is needed to 

test the operator.

H

H

KEY SWITCH BUTTON: 

Cycles operator when pressed.

I

I

RESET BUTTON: 

Resets circuit board.

1

7

6

5

4

3

2

CONTROL BOX MUST BE

PROPERLY GROUNDED!!

6004-066-C-1-13

Copyright 2013 DoorKing, Inc. All rights reserved.

Mounting Holes

9410

9409 

4302

D

D

12 

V

3 Amp/Hr Batter

y

12 

V

3 Amp/Hr Batter

y

G

J

Note: To turn-off ALL power to the operator, the AC 

power switch must be turned off AND the battery 

plug must be disconnected from the circuit board.

Thru-Bolt

The mounting bracket and motor can be 

flipped for right-side opening direction.

Remove cover and 2 thru-bolts to remove 

and install the mounting bracket.

Note: Lock and unlock directions will be reversed 

when motor is in the right-side orientation.

Manual Release

Right-Side Orientation

Left-Side Orientation

D

O

O

R

K

I N

G

Moto

r

Cover

Mo

untin

g

Bracket

Note: Linking arm must be in the center hole of the gate 

attachment bracket.

Opens to the

Inside

Position of Operator and Arms

Operator

Disassembly

Installing Mounting Bracket and Gate Attachment Bracket

12

34

56

7

12

34

56

7

C

B

A

90°

Linking Arm

“A” inches

“B” inches C max. inches

Gate Attachment Bracket

2.50 - 4.25
4.25 - 6.25
6.25 - 8.25
8.25 - 10.25
10.25 - 12.25
12.25 - 14.00

28.75
28.25
28.00
27.25
27.00
26.25

4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00

D O O R K I N G

D O O R K I N G

D O O R K I N G

A support bar must be used if the 

operator is mounted in the middle 

of the gate and span the entire 

length of the gate to support the 

gate pickets. The pickets will bend 

if not supported.

Top

Middle

Bottom

Left-Side Position

Right-Side Position

Support Bar

Securely mount control box near the operator 

with appropriate hardware (not supplied).

Coaxial

Cable

Antenna

(Not

Supplied)

Operator

Cable

Power

Loops

Control

Box

Unlock

Loc

k

Unloc

k

Lock

Operator Mounting

Options

Limit Switches

Top Limit

Ring

Bottom

Limit Ring

Limit LED

Slow Down LED

D

Circuit board power must be ON 

when adjusting the limit rings, LEDs 

will light while turning the limit rings.

J

Attach mounting bracket to pilaster or wall with four (4) #10 

screws and suitable expansion hardware (Not supplied).

Left-Side

“Bottom”

Position

shown.

1 5/8”

Brackets MUST be

installed level!

Weld gate attachment bracket to gate or 

use two (2) suitable screws (Not supplied).

Arms MUST be

installed level!

Brackets MUST be securely attached. 

Extreme force will be exerted on 

brackets during normal gate cycling.

White - Neutral

Black - 115 VAC Hot

Green - Chassis Ground

G

SINGLE/PRIMARY

Actuator Cable

Circuit Board

Connection

DO NOT connect the

Primary operator to

this connection.

Connect Secondary

operator ONLY.

Tip: 

Never run low voltage 

rated wire insulation in the 

same conduit as high voltage 

rated wire insulation. Keep 

them in separate conduits.

Wire Size

Distance

14 AWG
12 AWG

Up to 200 ft

Beyond 200 ft

115 VAC Input

Power Wire

Not included - Refer to a specific Radio 

Receiver Manual (available from 

www.dkaccess.com

) for more information on 

radio receivers and antenna installation. See 

reverse side for wiring.

1

23

A

B

1. Direction 

Primary

 operator opens.

2. OFF

3. OFF

4. 

ON          Auto-Close Timer

5. ON - Shadow Loop

6. OFF

7. OFF

8. OFF

Adjust 1 to 23 sec.

1. ON - Relay for Dual Plug-In Shadow Loop

2. OFF - Relay for Dual Plug-In Shadow Loop

3. OFF

4. OFF

SW 1

1

ON

2

3

4

5

6

7

8

SW 2

1

ON

2

3

4

Typical Settings for Single Operator with Plug-In Loops

See reverse side.

Note: Please refer to the 

Wiring/Owner’s manual for 

more information.

Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles.

Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the 

6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.

Low V

oltage

High V

oltage

Single Channel Exit

Plug-In Loop Detector

Dual Channel

Reverse and Shadow

Plug-In Loop Detector

Battery Plug

AC Power Switch

Not included - Refer to the Wiring/Owner’s 

manual and Loop Information Manual 

(available free from 

www.dkaccess.com

) for 

more information.

Relay must be set 

to N.O. for shadow 

loop.

NC

NO