Drive
Arm
Linking Ar
m
Arm Assembly
Install the gate attachment
bracket to the gate.
Lockpin
Lockpin
Retaining Ring
Spacing
Washers
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
CAUTION
RED 24V RE
D
BLK 115V WH
T
QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE”
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
115 VAC Connection
Battery Connection
1. Brown
2. Blue
3. Orange
4. Red
5. Yellow
6. Green
7. Green/Yellow
Operator
Cable
Loop Wires
Coaxial Cable Antenna
(Not Supplied)
Alarm
Reset
Com
Com
4 Open Input
5 Open Input
N.O.
Relay
24V
Chassis
Ground
Mounting
Hole
Radio Receiver
Tip:
It is recommended
that a surge suppressor
be installed on the high
voltage power lines.
DANGER
HIGH VOLTAGE!
Loop Detectors
Board Adjustments
C
C
A
B
F
F
C
C
E
E
Do not connect the battery plug to the
circuit board until power is needed to
test the operator.
H
H
KEY SWITCH BUTTON:
Cycles operator when pressed.
I
I
RESET BUTTON:
Resets circuit board.
1
7
6
5
4
3
2
CONTROL BOX MUST BE
PROPERLY GROUNDED!!
6004-066-C-1-13
Copyright 2013 DoorKing, Inc. All rights reserved.
Mounting Holes
9410
9409
4302
D
D
12
V
3 Amp/Hr Batter
y
12
V
3 Amp/Hr Batter
y
G
J
Note: To turn-off ALL power to the operator, the AC
power switch must be turned off AND the battery
plug must be disconnected from the circuit board.
Thru-Bolt
The mounting bracket and motor can be
flipped for right-side opening direction.
Remove cover and 2 thru-bolts to remove
and install the mounting bracket.
Note: Lock and unlock directions will be reversed
when motor is in the right-side orientation.
Manual Release
Right-Side Orientation
Left-Side Orientation
D
O
O
R
K
I N
G
Moto
r
Cover
Mo
untin
g
Bracket
Note: Linking arm must be in the center hole of the gate
attachment bracket.
Opens to the
Inside
Position of Operator and Arms
Operator
Disassembly
Installing Mounting Bracket and Gate Attachment Bracket
12
34
56
7
12
34
56
7
C
B
A
90°
Linking Arm
“A” inches
“B” inches C max. inches
Gate Attachment Bracket
2.50 - 4.25
4.25 - 6.25
6.25 - 8.25
8.25 - 10.25
10.25 - 12.25
12.25 - 14.00
28.75
28.25
28.00
27.25
27.00
26.25
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
4.25 - 5.00
D O O R K I N G
D O O R K I N G
D O O R K I N G
A support bar must be used if the
operator is mounted in the middle
of the gate and span the entire
length of the gate to support the
gate pickets. The pickets will bend
if not supported.
Top
Middle
Bottom
Left-Side Position
Right-Side Position
Support Bar
Securely mount control box near the operator
with appropriate hardware (not supplied).
Coaxial
Cable
Antenna
(Not
Supplied)
Operator
Cable
Power
Loops
Control
Box
Unlock
Loc
k
Unloc
k
Lock
Operator Mounting
Options
Limit Switches
Top Limit
Ring
Bottom
Limit Ring
Limit LED
Slow Down LED
D
Circuit board power must be ON
when adjusting the limit rings, LEDs
will light while turning the limit rings.
J
Attach mounting bracket to pilaster or wall with four (4) #10
screws and suitable expansion hardware (Not supplied).
Left-Side
“Bottom”
Position
shown.
1 5/8”
Brackets MUST be
installed level!
Weld gate attachment bracket to gate or
use two (2) suitable screws (Not supplied).
Arms MUST be
installed level!
Brackets MUST be securely attached.
Extreme force will be exerted on
brackets during normal gate cycling.
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
G
SINGLE/PRIMARY
Actuator Cable
Circuit Board
Connection
DO NOT connect the
Primary operator to
this connection.
Connect Secondary
operator ONLY.
Tip:
Never run low voltage
rated wire insulation in the
same conduit as high voltage
rated wire insulation. Keep
them in separate conduits.
Wire Size
Distance
14 AWG
12 AWG
Up to 200 ft
Beyond 200 ft
115 VAC Input
Power Wire
Not included - Refer to a specific Radio
Receiver Manual (available from
www.dkaccess.com
) for more information on
radio receivers and antenna installation. See
reverse side for wiring.
1
23
A
B
1. Direction
Primary
operator opens.
2. OFF
3. OFF
4.
ON Auto-Close Timer
5. ON - Shadow Loop
6. OFF
7. OFF
8. OFF
Adjust 1 to 23 sec.
1. ON - Relay for Dual Plug-In Shadow Loop
2. OFF - Relay for Dual Plug-In Shadow Loop
3. OFF
4. OFF
SW 1
1
ON
2
3
4
5
6
7
8
SW 2
1
ON
2
3
4
Typical Settings for Single Operator with Plug-In Loops
See reverse side.
Note: Please refer to the
Wiring/Owner’s manual for
more information.
Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the
6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.
Low V
oltage
High V
oltage
Single Channel Exit
Plug-In Loop Detector
Dual Channel
Reverse and Shadow
Plug-In Loop Detector
Battery Plug
AC Power Switch
Not included - Refer to the Wiring/Owner’s
manual and Loop Information Manual
(available free from
www.dkaccess.com
) for
more information.
Relay must be set
to N.O. for shadow
loop.
NC
NO