22
6500-065-K-7-08
3.1 Circuit Board Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
•
Auto close timer
(when turned on)
SW 1, switch 4.
Adjust from 1
second (full
counter clockwise)
to approximately
23 seconds (full
clockwise).
•
Dry relay contacts
(terminals 10-11) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on
the N.O. or N.C. pins
respectively.
Self test mode is for
bench checks only.
The operator will
continually cycle the
gate.
The jumper must be
set at normal mode
to function.
•
Set the DIP-switches on the
circuit board to the desired
setting. See switch-setting
charts on next page.
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
N.
C.
N.O.
SW 1
SW 1
Self Test
Mode
Normal
Mode
1
ON
2
3
4
SW 2
Loop Detector
Loop Detector
1
23
9410
EXIT
SHADOW
SHADOW OUTPUT
REVERSE
9409
Self Test
Auto Close Timer
DIP-Switches
Dry Relay Contact
•
Adjust reversing sensitivity
for PRIMARY (single) and
SECONDARY (dual) operators.
Min
Max
Secondary
Primary
Min
Max
Reverse Sensor