6550-065-A-4-12
26
4405
DANGER
HIGH VOLTAGE!
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
SELF
TEST
NC
NO
1
2
3
4
5
6
7
8
9
13
12
11
10
14
15
16
17
18
19
20
5.1 Terminal Description
SECTION 5 - MAIN TERMINAL WIRING
Low Voltage Common
Full Open
24 VAC - 250 ma max.
Full Open
Full Open
Standard Reverse
Gate Tracker Data
Gate Tracker Busy
24 VDC Mag Lock Power
Dry Relay Contact
Dry Relay Contact
Low Voltage Common
Low Voltage Common
Entrapment Alarm
Alarm Reset
Secondary Current Sensor
Motor
Motor
Circuit Board Power
Circuit Board Power
4405 Main Terminal
4
5
6
9
10 11
16
15
14
For dual operator applications
ONLY.
Allows the secondary
reversing sensor to monitor
the current flow into the
secondary operator. See page
22 for more information.
DoorKing’s Remote alarm reset
station can be connected. See
next page for wiring.
It MUST be mounted in the
line-of-sight of the gate
operator. (DKS P/N 1404-080)
Operation of the circuit board dry
relay contact is dependent on
setting of SW 1,
switches 7 and 8
.
Relay contacts
can be set for
Normally Open (NO) or
Normally Closed (NC)
operation.
Contact rating is
1 amp maximum
at 24-volts DC.
NO
NC
SW 1
1
ON
2
3
4
5
6
7
8
24-volt DC magnetic lock power is
provided constantly except when the
gate is
opening
or
open
(Normally
Closed function). 1 Amp Max.
SW 1
1
ON
2
3
4
5
6
7
8
•
lf SW 1,
switch 3
is
ON
, functions as a
normal full open input (Normal setting).
•
lf SW 1,
switch 3
is
OFF
, input to
terminal #4 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).
SW 1
1
ON
2
3
4
5
6
7
8
SW 1
1
ON
2
3
4
5
6
7
8
•
When gate is closed, input will open gate.
•
When gate is open and auto close timer SW 1,
switch 4 is turned
ON
, input will re-set and hold timer.
•
When gate is open and auto close timer SW 1,
switch 4 is turned
OFF
, input will close gate.
•
When gate is closing, input will reverse gate.
This input ONLY functions when gate is
fully opened
or in the
closing cycle
.
•
When gate is closing: SW 1,
switch 5
is
OFF,
an input to terminal #6 (e.g.: photo
beam gets obstructed) will stop and
reverse
and the gate to the full open position.
Note:
If the auto-close timer is
ON
, when
gate reaches the open position, timer
will
not
close the gate. Another input command
is needed to reset and close the gate (Normal
Setting).
•
Do Not
use SW 1,
switch 5
ON,
for the 6550.