5
Fresh air circulation is required
The DLoG X device employs a passive cooling concept whereby the waste heat
generated inside the device is emitted from the surface of the housing. For this system
to function properly, sufficient fresh air circulation is required. Never install the system
in a closed environment where the cooling air is unable to dissipate accumulated heat
to the outside.
If the DLoG X device is not able to draw in fresh cooling air, this may cause
overheating and severe damage to the unit. Be sure to comply with the maximum
ambient temperature to guarantee correct operation (as specified in
Mounting / Initial operation
The device is not supplied with a disconnector (switch) that can be accessed
externally. The power supply connector is therefore used as a disconnector.
This must always be easily accessible. If the device is permanently installed,
an easily accessible disconnector (such as a switch or automatic circuit breaker)
needs to be additionally installed.
The power supply cables must be laid in accordance with the applicable local
installation regulations.
Risk of injury
The unit could fall during transit or installation and cause injury. Always enlist the aid
of a second person for installing or removing the unit.
Summary of Contents for DLoG X 10
Page 1: ...3 10 DLoG X 7 DLoG X 10 DLoG X 12 Manual ...
Page 3: ......
Page 12: ......
Page 55: ...Initial operation DLoG X Series Manual 43 COM2 Options 13 Audio Option ...
Page 87: ...Boot loader DLoG X Series Manual 75 Figure 9 2 Boot loader diagram 2 ...
Page 109: ...Audio Option DLoG X Series Manual 97 Figure 13 2 Audio port circuit diagram ...