Mounting
DLoG X Series
Manual
63
7.5.1.
DC terminals
In DC-powered devices, always attach ring tongue on the supply voltage cable to the
ground bolt situated on the connector bay.
Figure 7.1: Position of the ground bolt
•
The other end of the yellow-green supply voltage cable has to be connected to the
vehicle’s chassis
•
Make sure that the DLoG X device’s connecting cable is terminated as close to the
battery as possible. Connecting the DLoG X device to large electrical loads, such as
converters for the forklift motor may result in random restarts, malfunctions and/ or
irreparable equipment damage to the system.
•
If you want to connect devices fed by other power sources to the DLoG X device
(e.g. certain printers), make sure to power up the peripheral devices
at the same
time or
after
the DLoG X device. Otherwise, you may encounter start-up problems,
malfunctions or even irreparable damage to your system