Securing the unit

We  recommend  that  you  secure  the  unit  to  the  concrete  pad  by  using  four  (4)  TAPCON  screws  and  washers. 
(See drawing below.)

//,0)%304-00$A

0FB00BB

Condensation and Drainage

The evaporator coil will produce condensation while the unit is running and drain at a steady rate, usually 11 to 19 liters,
depending on the ambient air temperature and humidity.

It is normal for condensation to drip out the 

CONDENSATION WATER DRAIN PIPE

that is located on the side of the unit.

(See drawing below.)

A: 

Concrete Pad

B: 

1/4” x 1-1/2” Stainless Steel Concrete Screw 

and Washer (Provided by installer)

C: 

3/16” Drilled Hole

3” minimum

A

B

C

A: 

CONDENSATION WATER DRAIN PIPE

B: 

WINTERIZING DRAIN (with plastic caps)

A

B

C/-&%0()0'%,/10),7'31+'%00%1%00+2'+.%20$75

BFF

Para un rendimiento óptimo de la bomba de calor, siga las siguientes instrucciones:

Lave regularmente el filtro de la piscina contracorriente para que el caudal de circulación del agua sea constante en la
bomba de calor.

Mantenga la superficie del serpentín (evaporador) limpia y sin restos de papel, hojas u otros desechos. Los puede quitar fá-
cilmente con un chorro de agua de baja presión sin dañar las aletas de aluminio.

Limpie cuidadosamente el aparato con un limpiador suave no abrasivo y sin blanqueador (lejía); enjuáguelo con una manguera
sin lanza de riego.

Advertencia:

Antes de efectuar cualquier tipo de trabajo en la bomba de calor, corte la corriente con el disyuntor del circuito de 
alimentación eléctrica

Summary of Contents for 100 HPRA-E-410

Page 1: ...0HPRA E 410 50HPRA E 410 80 HPRA E 410 100 HPRA E 410 50HPRA E 410 3PH 80HPRA E 410 3PH 100HPRA E 410 3PH POOL HEAT PUMP THERMOPOMPES POUR PISCINE BOMBA DE CALOR ELÉCTRICA PARA PISCINAS 43 de l Alcazar Blainville Québec Canada J7B 1R4 www dpopool com MDPL 00001A E ...

Page 2: ......

Page 3: ...arning Prior to starting the heat pump you must ensure that Electricity is supplied to the heat pump The filter pump is operating with a minimum water circulation of 5 1 m3 h with a maximum pressure of 3 BARS If these two conditions are not met the heat pump with not start In such case the digital display thermometer will be unusable C 0 0 10 7 31 00 1 00 2 20 83 B ...

Page 4: ...a un voltaje inadecuado a fusibles quemados y a disyuntores de circuito abiertos Tampoco se hace responsable de los daños causados por insuficiencia o interrupción del servicio de alimentación eléctrica Los daños o reparaciones debidos a un uso inadecuado abusivo reparaciones inadecuadas modificaciones no autorizadas o mal funcionamiento Los daños debidos a inundaciones viento incendios rayos acci...

Page 5: ... Para seleccionar una función F0 F8 presione el botón o Una vez seleccionada la función usted debe presionar el botón con el fin de modificar el valor por defecto Para modificar el valor por defecto usted debe presionar los botones o Una vez modificado el valor por defecto presione el botón para regresar a la etapa anterior con el fin de seleccionar otras funciones F0 F8 Para salir del modo de pro...

Page 6: ...y 16 35 C 60 95 F 16 35 C 60 95 F 16 35 C 60 95 F itanium Titanium Titanium Double coil Double coil Double coil R410A R410A R410A 2 0 2 65 3 2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Rotary Scroll Scroll Included Included Included 14 21 26 5 2 65 4 7 6 3 5 3 4 5 4 2 55 59 61 5 1 8 2 8 2 15 15 15 1255 1255 1255 930 1135 1135 415 415 415 88 128 128 1275 1275 1275 960 1360 1360 480 480 480 95...

Page 7: ... 30 4 00 6 B F 0 FDB C 0 0 10 7 31 00 1 00 2 20 79 E B D 0EF0B F B El termostato con pantalla digital no funciona El disyuntor eléctrico se ha disparado Póngalo en su posición inicial El caudal de agua es insuficiente o la bomba de filtración no funciona La bomba de calor DPL ha sido diseñada para funcionar con una circulación de agua mínima de 5 1 m3 h Ponga en marcha la bomba Cuando resulte impo...

Page 8: ...5 minute time delay The pilot light will blink during this 5 minute time delay To display the temperature in farenheit F or celcius C Press the and buttons simultaneously for 3 seconds to select the desired temperature scale Warning Prior to starting the heat pump you must ensure that There is electricity supplied to the heat pump The filter pump is operating with a minimum water circulation of 6 ...

Page 9: ...emove the water from the heat exchanger you must remove the drain cap WINTERIZING DRAIN that is located on the side of the unit You must then let the water flow out until the unit is completely emptied See the illustration below It is recommended to cover the heat pump with a protective cover that is available from your dealer 0 30 4 00 8 F F B 0 B 0 0 FB 0 0 F B A WATER INLET B WATER OUTLET C CON...

Page 10: ...P30012 P30061 P30057 P30058 50HPRA R410 100HPRA R410 P20001 P20001 P20003 P20016 P20004 P20004 P20002 P20017 P20006 P20018 P20005 P20019 P20007 P20007 P20008 P20008 P20020 P20020 P30045 P30046 P30020 P30020 P30081 P30081 P30082 P30083 P30142 P30142 P10118 P10118 P10117 P10117 P30047 P30047 P30062 P30064 P30036 P30149 P30149 P30076 P30076 P30050 P30050 P30034 P30035 P30103 P30103 P30099 P30026 P300...

Page 11: ... B C A CONDENSATION WATER DRAIN PIPE B WINTERIZING DRAIN with plastic caps A B C 0 0 10 7 31 00 1 00 2 20 75 B F F Para un rendimiento óptimo de la bomba de calor siga las siguientes instrucciones Lave regularmente el filtro de la piscina contracorriente para que el caudal de circulación del agua sea constante en la bomba de calor Mantenga la superficie del serpentín evaporador limpia y sin restos...

Page 12: ...tubos Conecte los tubos de PVC rígido categoría 40 con los orificios de entrada y salida de la bomba de calor Las juntas deben pegarse con cola para PVC Si no dispone de tubos rígidos utilice tubos flexibles con abrazaderas de acero inoxidable Cuando haya terminado de instalar los tubos ponga en marcha la bomba de la piscina y verifique si hay fugas Válvula de retención y bucle para productos quím...

Page 13: ...here voltage or phase imbalances may occur above or below permissible limits WARNING Disengage main power disconnect before attempting installation C 0 0 10 7 31 00 1 00 2 20 72 E B B B0EF0DBC FBE A B D A Disconnect switch B Electrical conductor C Electrical connection box cover D Terminal block E Terminal block 3 PH C E Ventilador Ventilador Protección de fase Protector de presión alta Protector ...

Page 14: ...aracterísticas eléctricas El aparato ha de ser instalado por una persona calificada en conformidad a las ordenanzas y códigos nationales NFC 15 100 Los cables de suministro de energía deben contar con una certificación YZW y su peso no debe ser inferior al establecido por el código de designación 60245 IEC 57 La alimentación de la bomba de calor debe efectuarse mediante un circuito eléctrico exclu...

Page 15: ...ne C 0 0 10 7 31 00 1 00 2 20 68 B BD 0EF0 B0C CB0EF0DB Fijación del aparato Le aconsejamos fijar el aparato sobre una losa de hormigón mediante cuatro tornillos TAPCON y arandelas Véase la ilustración de abajo Condensación y drenaje El serpentín del evaporador produce condensación cuando el aparato funciona La condensación se drena a un ritmo constante de 11 a 19 litros según la temperatura ambie...

Page 16: ... la bomba de calor en posición ON Ponga en marcha la bomba y regule la temperatura a su gusto Al terminar la temporada preparación para el invierno Apague el disyuntor que alimenta la bomba Hay que sacar toda el agua del aparato Desconecte los conductos de ENTRADA DE AGUA y de SALIDA DE AGUA de senroscando los dos empalmes de la parte delantera del aparato Para eliminar totalmente el agua en el in...

Page 17: ...diciones de funcionamiento inseguras y peligrosas que anularían la garantía de fábrica Antes de empezar la instalación lea estas instrucciones así como todas las instrucciones que acompañen a otros ele mentos del sistema empaquetados por separado Le rogamos que lea todas estas instrucciones atentamente antes de empezar a instalar o a utilizar la bomba de calor Si no se siguen estas instrucciones p...

Reviews: