SuperSigma2 AM PMS
–
V1.5.6 17-1-2020
Page 59 (97)
©2019 DMC GmbH Herten Germany
Cal.
Ref.
Parameter
Calibrator
text
Options (defaults are in bold)
Range
21
Drive Output Controller
Temp TH
CtrTmpTh
Adjustable from 10 to 100 °C.
Default is 45 °C
10
–
100
°C
22
n/a
23
Calibration Data Options
CalValue
Not active
---
24*
Loading Default
LoadDefs
0 = Don't load defaults
1 = Load defaults
0
–
1
(*) Recycle the key switch to make changes active. (Also indicated on calibrator ‘key’)
M3-1P
Accel. Characteristic
”
Lin/Curv
”
See “
in the paragraph 5.1 Menu 3
M3-2P
Speed 6 input normally closed or normally open
“
Sp6NO/NC
”
This sets the active polarity of input pin 6 on 35-Way Connector.
•
If set to
0 (NO)
, the input will be active when a switch connected to pin 6 is closed.
•
If set to
1 (NC)
, the input will be active when a switch connected to pin 6 is open.
M3-3P
Inhibit input normally closed or normally open
“
HibNO/NC
”
This sets the active polarity of input pin 7 on 35-Way Connector.
•
If set to
0 (NO)
, the input will be active when a switch connected to pin 7 is closed.
•
If set to
1 (NC)
, the input will be active when a switch connected to pin 7 is open.
If inhibit input (
Pin 7 Speed Limit 3 / Handbrake --
) becomes active, it immediately stops the pump and
signals failure (F 03). Inhibit input is not active on input 6 (Power steer), thus if input 6 is active and inhibit is activated
the pump is still work signaling failure (F 03).
M3-4P
Enable power up checks
“
Nchk/Chk
”
This sets whether or not the pump inputs and short circuit are checked at power-up.
•
If set to
0 (NO check)
, then the following power-up safety checks will not be performed:
i.
Line contactor short circuit test.
ii.
Pump potentiometer > 0.5% or Speed 1 switch closed (depending on the setting of
).
iii.
Speed 2, 3, 4 or 5 closed.
•
If set to
1 (Check)
, then the safety checks will be performed at power-up. If one of the inputs is active at power
up the pump is kept locked and failure
F12 is displayed. Input 6 “power steer” is not checked.
M3-5P
Enable pot with switch
“
NoSw/Sw
”
Some lift levers are fitted with an integrated switch. This parameter allows the option of checking the switch or pump
potentiometer at power-up.
•
If set to
0 (NoSw)
, a potentiometer without an integrated switch connected to pin 1 can be used.
•
If set to
1 (Sw)
, then a potentiometer with a switch can be connected to pin 1.